Henry constants and gas solubility from σ-profiles
Henry constants follow from an infinite-dilution activity coefficient times a vapour pressure. σ-profiles give the first, measurement must give the second.
Updated November 28, 2026
A Henry constant measures how much of a volatile solute a liquid holds at a given partial pressure. For a solute that is itself a liquid at the working temperature, the Henry constant equals the infinite-dilution activity coefficient times the pure-component vapour pressure. A COSMO-RS style model computes the first factor from the σ-profiles of solute and solvent. The second must be measured. For permanent gases above their critical temperature the second factor does not exist, and sigma profiles then rank solvents but do not give absolute values without an anchor.
Henry's law and its several unit conventions
Henry's law states that at low concentration the partial pressure of a solute above a solution is proportional to its amount in the solution. The proportionality constant is the Henry constant, and the law has at least three common forms. The pressure over mole fraction form has units of pressure, and a large value means a volatile, poorly soluble solute. The concentration over pressure form has units of moles per volume per pressure, and a large value means a soluble solute. The dimensionless form divides a gas-phase concentration by a liquid-phase one, and each form also exists as its reciprocal.
The Wikipedia article on Henry's law tabulates the conversions. Before you compare any computed value with a literature one, write down which form each uses and at what temperature. The NIST Chemistry WebBook lists measured constants for many gas and water pairs with the convention stated.
The route through the infinite-dilution activity coefficient
At low mole fraction the modified Raoult's law gives the partial pressure as mole fraction times activity coefficient times pure-component vapour pressure. The activity coefficient tends to its infinite-dilution value. Dividing by the mole fraction gives the Henry constant in the pressure over mole fraction form as the infinite-dilution activity coefficient times the vapour pressure. That single line is the connection between σ-profiles and gas solubility.
The guide on infinite-dilution activity coefficients explains how a COSMO-RS style model gets the first factor from the σ-profiles of the solute and the solvent. The vapour pressure is the second factor, and the guide on vapour pressure and σ-profiles explains why it must come from measurement rather than from the profile. The σ in a .mfsig file is the raw per-segment screening charge density, not the averaged σ that COSMO-RS and COSMO-SAC parameterisations expect, and it must be averaged before this step.
One useful consequence follows. When you compare solvents for the same solute, the vapour pressure is common to all of them and cancels in the ranking. The order of the Henry constants across solvents is the order of the infinite-dilution activity coefficients. A solvent in which the solute has a low activity coefficient holds it tightly and has a low Henry constant in the pressure form. No measurement is needed for the ranking, only for the absolute scale.
Permanent gases and the missing vapour pressure
Oxygen, nitrogen, hydrogen, methane and carbon dioxide are above their critical temperatures at ordinary conditions. There is no pure liquid and no vapour pressure to multiply by. The route through the activity coefficient then needs a substitute reference, and there are two ways to build one.
The first is the gas-phase route. The free energy of transfer from the gas to the solution at infinite dilution comes from the chemical potential of the solute in the solvent, which the σ-profiles give, minus the gas-phase chemical potential, which needs the gas-phase energy of the molecule and the fitted gas-phase parameters of a COSMO-RS implementation. A .mfsig file holds the solvent-phase calculation only, so this route needs a second calculation and a model.
The second is the anchor route. Measure or look up the Henry constant of the gas in one solvent, compute the ratio of activity coefficients between that solvent and every other candidate from the σ-profiles, and scale. This gives absolute values for the whole solvent set from one measurement, and it is how a screening study usually proceeds.
Carbon dioxide in amine solutions is a different problem. The gas reacts to form carbamate or bicarbonate, and the uptake is chemical absorption rather than Henry's law solubility. A σ-profile of carbon dioxide says nothing about that reaction.
A worked example, recovering toluene from an air stream
Suppose a process team wants to absorb toluene vapour from air and is choosing between water, a long-chain alkane oil and a polyether solvent.
- Obtain σ-profiles of toluene and of each solvent, and average the raw σ.
- Compute the infinite-dilution activity coefficient of toluene in each solvent with a COSMO-RS style model.
- Rank the solvents. Water gives toluene a very large activity coefficient, because the aromatic surface finds no matching polar surface. The alkane oil gives a value near one. The polyether lands in between.
- Take the vapour pressure of toluene at the operating temperature from an Antoine fit in the NIST Chemistry WebBook.
- Multiply to get a Henry constant in the pressure form for each solvent.
The ranking in step 3 already answers the design question, and the alkane oil wins on solubility alone. Steps 4 and 5 give the absolute capacity, which sets the solvent flow rate. Toluene is a liquid at room temperature, so the vapour pressure exists and the route is complete. The primer on σ-profiles in process chemistry sets this calculation among the others a process team runs.
What else the single file fixes
A gas molecule is rigid, so the single-conformer limitation of a .mfsig file hardly matters for the solute. It matters for flexible solvents, where one embedded conformer gives one σ-profile. Temperature matters more. The σ-profile has no temperature of its own, and the COSMO-RS style model carries the temperature dependence of the activity coefficient only through its own expressions. Henry constants of gases in water change strongly with temperature, so state the temperature with every value. Ionic solvents bring their own issues, which the guide on ionic liquids and σ-profiles describes.
Key points
- For a solute that is a liquid at the working temperature, the Henry constant in the pressure form equals the infinite-dilution activity coefficient times the pure-component vapour pressure.
- σ-profiles supply the activity coefficient after averaging. The vapour pressure must be measured.
- Ranking solvents for one solute needs no measurement at all, because the vapour pressure cancels.
- Permanent gases have no vapour pressure. Use a gas-phase reference with a model, or anchor the ranking with one measured Henry constant.
- Always state the Henry constant convention and the temperature.
Questions people ask
- How is a Henry constant related to the activity coefficient?
- For a solute that is a liquid at the temperature of interest, the Henry constant in the pressure over mole fraction form equals the infinite-dilution activity coefficient times the pure-component vapour pressure. A COSMO-RS style model gives the activity coefficient from the σ-profiles of solute and solvent. The vapour pressure must come from measurement.
- Can σ-profiles predict the solubility of oxygen or carbon dioxide in a solvent?
- Only partly. Those gases are above their critical temperature at room temperature, so there is no pure-liquid vapour pressure to multiply by. An absolute Henry constant then needs a gas-phase reference energy and model parameters that a σ-profile does not contain. The σ-profiles still rank solvents for the same gas, and one measured value can anchor the ranking.
- Which Henry constant convention should I use?
- State it every time. The pressure over mole fraction form has units of pressure and is large for poorly soluble gases. The concentration over pressure form has units of concentration per pressure and is large for soluble gases. A dimensionless form divides a gas-phase concentration by a liquid-phase one. The same physical solubility gives numbers that differ by orders of magnitude between conventions.
Further reading
In practice: σ-moments, HOMO and LUMO in solvent, the dipole norm, the reaction-field energy and the cavity area are all fields of a .mfsig file; the anatomy page lists them with their units.
Generate a σ-profile from your SMILES