mfsig.com
ionic-liquidsionselectrolytessolvent-design5 min read

Ionic liquids and σ-profiles, one ion at a time

An ionic liquid enters a σ-profile model as two separate ions with charge-shifted profiles, so cations and anions can be screened before any synthesis.

Updated November 28, 2026

An ionic liquid is a salt that is liquid near room temperature, and in a σ-profile model it is two molecules, not one. You compute the cation and the anion separately, each with its full charge, and treat the liquid as an equimolar mixture of the two. Each ion has a σ-profile shifted away from zero by its charge, and the pair's complementary profiles explain why the salt is a liquid and how it solvates. The approach lets you screen hundreds of cation-anion combinations from a few dozen ion profiles, before any synthesis.

Why two profiles and not one

A sigma profile model builds a liquid from independent surface segments. An ion pair treated as one neutral molecule freezes one relative orientation of cation and anion, and the resulting profile depends on which orientation was chosen. Treating the ions separately lets the model pair every cation segment with every anion segment according to the pair energies, which is what a liquid does. It also makes the library combinatorial. Twenty cations and twenty anions give four hundred ionic liquids from forty calculations.

The price is that the model must handle charged species. In a conductor-like continuum the screening charge on an ion's surface integrates to approximately minus the ion's charge, scaled by the dielectric factor f(ε) = (ε − 1)/(ε + x). For a cation the whole profile shifts to negative σ. For an anion it shifts to positive σ. The guide on σ-profiles of ions and zwitterions explains the shift in detail.

Reading a cation and an anion profile

Take 1-butyl-3-methylimidazolium as the cation. Its σ-profile has a broad region at mildly negative σ from the butyl chain and the ring carbons, where the positive charge is spread thin, and sharper negative peaks from the three ring hydrogens, especially the one between the nitrogens, which is acidic and a recognised hydrogen-bond donor. Nothing sits at positive σ, because every surface of a cation is screened by negative conductor charge.

Now take three anions. Tetrafluoroborate has a compact surface at moderately positive σ, with the charge spread over four fluorines, so it is a weak hydrogen-bond acceptor. Bis(trifluoromethanesulfonyl)imide is larger, with its charge diluted over oxygens, nitrogen and fluorines, so its profile sits closer to zero and it is weaker still. Acetate concentrates its charge on two oxygens and shows a sharp peak at strongly positive σ, making it a strong acceptor. These differences are the whole story of anion effects in ionic liquids, and they are visible in the profiles before any model runs. Reading donor and acceptor peaks works for ions as it does for neutral molecules.

Computing ions with MFsig

MFsig takes the SMILES as written, charge included, and computes it in a C-PCM continuum with ε = 80. A multi-fragment SMILES such as a cation and anion written together with a dot is reduced to the fragment with the most heavy atoms, and the rest is recorded as dropped in the .mfsig file. To get both ions you order two files, the cation SMILES with its positive charge and the anion SMILES with its negative charge. The guide on salts and multi-fragment SMILES covers the mechanics.

Two recipe details matter for ionic liquids. Anions containing iodine or heavier elements use a def2 effective core potential, because the recipe applies one to elements with Z of 37 and above. And the raw σ written to the file is the screening charge per segment divided by segment area, not the averaged σ that COSMO-RS and COSMO-SAC parameterisations expect. For ions, averaging also matters for the integrated charge, so apply the model's scheme to each ion's segments before building the profiles and check that the total charge is conserved.

A worked screen, anions for dissolving cellulose

Cellulose dissolves in some ionic liquids because the anion breaks the hydroxyl network that holds the chains together. To screen anions, compute the σ-profile of a cellulose fragment, a cellobiose unit or a methylated glucose as a stand-in, and the profiles of a fixed cation with each candidate anion. Run a COSMO-RS-type model for the fragment at infinite dilution in each ionic liquid and rank by ln γ∞.

The ranking follows the anion's acceptor strength. Acetate and chloride, with sharp peaks at strongly positive σ, pair with the cellulose hydroxyls and give the lowest ln γ∞. Tetrafluoroborate and the triflimide anion, with diluted charge, give far higher values. This is the trend reported for cellulose solubility in imidazolium ionic liquids, and the model reproduces its direction from the profiles alone. The same screen, with a different solute, serves extraction of aromatics from aliphatics, capture of carbon dioxide, or the solvation of a lithium salt in an electrolyte, see σ-profiles for battery electrolyte design.

Where the model strains

Three limitations recur. Small, highly charged ions such as chloride and fluoride concentrate their screening charge on a small surface, and the pair-contact energies grow large relative to RT, which stretches the model's assumptions. Strong cation-anion association means the ions are not independent segments, and some implementations add an ion-pair correction. And ionic liquids are often wet, since many are hygroscopic, so a real screen should include water as a third component, which the mixture formalism allows. The viscosity, melting point and electrochemical window of the liquid are outside the σ-profile.

MFsig produces the ion profiles, each with a pinned recipe and a content hash. The ionic liquid predictions, and their accuracy statements, live on MolForge. The guide on deep eutectic solvents extends the same two-ion treatment to a related class of designer solvents.

Key points

  • An ionic liquid enters a σ-profile model as two separate ions, which makes a library of cations and anions combinatorial.
  • A cation's profile is shifted to negative σ and an anion's to positive σ, and the anion's acceptor peak governs most solvation trends.
  • MFsig computes one fragment per SMILES, so order the cation and the anion separately with their charges.
  • Average the raw σ of each ion with the model's scheme and check that the total charge is conserved before use.
  • Small ions, strong association and water content are where the predictions deserve the most caution.

Questions people ask

How is an ionic liquid represented in a σ-profile calculation?
Usually as two separate molecules, the cation and the anion, each computed on its own with its full charge. The liquid is then treated as an equimolar mixture of the two ions. An alternative computes the ion pair as one neutral unit, which fixes one contact geometry and is less general.
What does the σ-profile of a cation look like?
Its screening charge is shifted to negative σ because the conductor must counter a positive ion. Most of the surface sits at mildly negative values, with sharper negative peaks at acidic hydrogens such as the imidazolium ring hydrogens. The anion's profile is the mirror case, shifted to positive σ.
Can MFsig compute an ionic liquid from a single SMILES with both ions?
Not as one calculation. A multi-fragment SMILES is reduced to the fragment with the most heavy atoms, and the others are recorded as dropped. Order the cation and the anion as two separate SMILES, each carrying its charge, and combine the two files downstream.
How reliable are σ-profile models for ionic liquids?
They reproduce trends in anion and cation effects on solubility and extraction well enough to screen, but the pair-contact picture strains for small, highly charged ions and for strong ion-ion association. Treat the output as a ranking tool, not as a replacement for a measured value.

Further reading

In practice: MFsig provides the σ-profile and descriptors; the downstream solubility and compatibility predictions live on the MolForge platform (solubility matrix, polymer lab) and carry their own accuracy statements there.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.