mfsig.com
vapour-pressureactivity-coefficientraoultgas-phase5 min read

Vapour pressure and σ-profiles, what the profile cannot give

A σ-profile gives activity coefficients, not vapour pressure. The pure-liquid reference and a gas-phase energy are missing, and here is where to get them.

Updated November 28, 2026

A σ-profile describes a molecule in a liquid and gives activity coefficients. Vapour pressure needs more, the free energy of the molecule in the gas relative to its pure liquid, and that reference is not in the profile. A .mfsig file holds no gas-phase energy, so it cannot give a vapour pressure on its own. What it can do is turn a measured pure-component vapour pressure into partial pressures over mixtures, and rank solvents for how tightly they hold a solute.

What vapour pressure is, in thermodynamic terms

A pure liquid and its vapour are in equilibrium when the chemical potential of the molecule is the same in both phases. The vapour pressure is the pressure at which that happens. Writing it out, the logarithm of the vapour pressure is proportional to the difference between the chemical potential of the molecule in its own liquid and a gas-phase reference, divided by RT. The liquid side is what COSMO-RS computes from a σ-profile. The gas side is a separate quantity.

In Klamt's formulation the gas-phase chemical potential is built from the difference between the gas-phase quantum-chemical energy and the energy in the conductor, plus a small set of fitted parameters, an element-specific gas-phase correction and a ring correction among them. The 1998 refinement paper lays this out. Every piece of the gas side needs either a second calculation in vacuum or a parameter that lives in a COSMO-RS implementation, not in the σ-profile.

What the σ-profile does carry

The liquid side is rich. From the σ-profiles of a solute and a solvent, a COSMO-RS style model gives the chemical potential of the solute in that solvent and in its own liquid, and the difference is the activity coefficient. The guide on activity coefficients from σ-profiles walks through the steps, and the guide on infinite-dilution activity coefficients covers the dilute limit that matters most for volatility.

With an activity coefficient in hand, the modified Raoult's law gives the partial pressure of a component over a mixture. The partial pressure equals the mole fraction times the activity coefficient times the pure-component vapour pressure. The σ-profile supplies the middle factor. Measurement supplies the last one. A positive deviation from Raoult, which is an activity coefficient above one, means the component is pushed out of the liquid and its partial pressure is higher than the ideal value. That is how a σ-profile speaks about volatility.

The σ in a .mfsig file is the raw per-segment screening charge density. It must be averaged before any COSMO-RS or COSMO-SAC parameterisation will treat it as the σ-profile those models expect, and the guide on COSMO-RS explained describes where the averaging sits in the chain.

What the σ-profile does not carry

Four things are absent, and each one is needed for an absolute vapour pressure.

  • The gas-phase electronic energy of the molecule. The file holds only the solvent-phase calculation.
  • The fitted gas-phase parameters of a COSMO-RS implementation. They belong to the model, not to the molecule.
  • Thermal and vibrational contributions to the free energy of each phase. Neither phase is treated beyond the electronic energy in a σ-profile calculation.
  • The enthalpy of vaporisation and its temperature dependence. The σ-profile is a single-temperature surface description.

The result is that a σ-profile predicts how a vapour pressure changes with composition, not what it is for the pure substance. Anyone who quotes a vapour pressure from a σ-profile alone has added a reference from somewhere else, and that somewhere else should be named.

Where to get the pure-liquid reference

Measured data come first. The NIST Chemistry WebBook lists Antoine equation parameters for many compounds, each with the temperature range over which the fit is valid. The Antoine form expresses the logarithm of the vapour pressure as A minus B over C plus T, with three fitted constants. Stay inside the stated range.

When no measurement exists, the Clausius–Clapeyron equation relates vapour pressure at two temperatures to the enthalpy of vaporisation. With a known normal boiling point and an estimate of the enthalpy from Trouton's rule, which puts the entropy of vaporisation of many liquids near 85 to 88 J per mole per kelvin, you get a rough value. Group-contribution methods give another estimate. A COSMO-RS implementation with its own gas-phase run and parameters gives a third, and the open implementation openCOSMO-RS shows what such a run needs.

A worked example, ethanol over an ethanol–water mixture

Ethanol boils near 78 °C at atmospheric pressure and water at 100 °C, in standard tables. Suppose you want the partial pressure of ethanol over a dilute aqueous solution at 25 °C.

  1. Obtain σ-profiles of ethanol and water, average the raw σ, and compute the activity coefficient of ethanol at the mole fraction of interest with a COSMO-RS style model.
  2. Take the Antoine parameters of ethanol from the NIST Chemistry WebBook and evaluate the pure-component vapour pressure at 25 °C, checking the valid range.
  3. Multiply mole fraction, activity coefficient and pure-component vapour pressure.

Ethanol in water shows a positive deviation, so the activity coefficient is above one in dilute solution and the partial pressure is above the Raoult value. The σ-profile made that prediction. The Antoine fit made the number absolute. For a solute above its critical temperature the second step fails, because there is no pure-liquid vapour pressure to look up, and the guide on Henry constants and gas solubility takes up that case.

Key points

  • Vapour pressure needs the chemical potential of the pure liquid and a gas-phase reference. The σ-profile gives the first and not the second.
  • A .mfsig file holds no gas-phase energy, so no vapour pressure can be derived from it alone.
  • The σ-profile gives activity coefficients, which convert a measured pure-component vapour pressure into partial pressures over mixtures through the modified Raoult's law.
  • Pure-component vapour pressures come from Antoine fits in the NIST Chemistry WebBook, or from Clausius–Clapeyron estimates when nothing is measured.
  • Raw σ must be averaged before COSMO-RS or COSMO-SAC style use.

Questions people ask

Can I calculate vapour pressure from a sigma profile?
Not from the σ-profile alone. Vapour pressure is set by the free energy difference between the pure liquid and the gas. The σ-profile describes the liquid side, but the gas side needs the molecule's gas-phase energy and, in COSMO-RS, a few empirical gas-phase parameters. A .mfsig file contains neither. Combine the profile with a measured vapour pressure instead.
What can a σ-profile tell me about volatility then?
It gives activity coefficients, which turn a known pure-component vapour pressure into partial pressures over a mixture through the modified Raoult's law. It also ranks solvents for how strongly they hold a given solute, because a higher activity coefficient means a higher partial pressure at the same mole fraction. The σ must be averaged first for COSMO-RS style use.
Where do I get a reliable pure-component vapour pressure?
From measured data. The NIST Chemistry WebBook lists Antoine equation parameters with their valid temperature ranges for a large number of compounds. When nothing is measured, the Clausius–Clapeyron equation with a boiling point and an estimated enthalpy of vaporisation gives a rough value, and group-contribution methods give another.

Further reading

In practice: σ-moments, HOMO and LUMO in solvent, the dipole norm, the reaction-field energy and the cavity area are all fields of a .mfsig file; the anatomy page lists them with their units.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.