mfsig.com
temperaturevan-t-hoffsolubilitythermodynamics5 min read

Temperature dependence of solubility predictions

Solubility changes with temperature via the fusion term and the activity coefficient. A σ-profile model handles both, with the van 't Hoff slope as the check.

Updated November 28, 2026

Solubility depends on temperature through two separate channels. The fusion term shrinks as the working temperature rises toward the melting point, and the activity coefficient changes because every contact energy in the liquid is weighed against RT. A σ-profile model captures both. The σ-profile itself is temperature-independent, a property of the molecule in a conductor, and temperature enters only in the statistical thermodynamics built on top of it. The van 't Hoff slope, the enthalpy of solution, is the single number that checks the prediction against experiment.

Two channels for temperature

Start from the solubility equation for a solid, ln x_sat = −ΔG_fus/RT − ln γ. The first term is −(ΔH_fus/R)(1/T − 1/T_m) when the enthalpy of fusion is constant. It rises toward zero as T approaches T_m, and the solubility rises with it. This channel is solvent-independent and often dominant for high-melting solids.

The second term is where the solvent lives. A sigma profile model computes ln γ from the contact energies between the solute's surface segments and the solvent's. Each energy is compared with RT in a Boltzmann factor. When the liquid is heated, an unfavourable contact costs relatively less and a favourable hydrogen bond buys relatively less. Activity coefficients above one therefore fall toward one as the temperature rises, and those below one rise toward one. For most organic solids in most solvents γ is above one, so both channels push solubility upward with temperature. The guide on the melting point and the fusion term treats the first channel in detail.

The van 't Hoff equation as the check

Differentiating ln x_sat with respect to 1/T gives the van 't Hoff relation, d ln x / d(1/T) = −ΔH_sol/R, where ΔH_sol is the enthalpy of solution. It is the sum of the enthalpy of fusion and the partial molar enthalpy of mixing of the solute in the saturated solution. A plot of ln x against 1/T is close to a straight line over a few tens of degrees, and its slope is the first thing to compare between prediction and measurement.

A σ-profile model gives the mixing part. Within COSMO-RS the temperature derivative of the chemical potential can be evaluated, and implementations differ in how the hydrogen-bond term scales with temperature. The fusion part comes from the melting data. If the predicted slope is right and the intercept is wrong, the solvent-solute interaction is right and the fusion term is suspect, often because the enthalpy of fusion was estimated rather than measured. If the slope is wrong, the interaction model needs a second look.

A worked extrapolation

Suppose a model, with measured melting data, gives an enthalpy of solution of 25 kJ/mol for a drug in ethanol. The snippet extrapolates a solubility from 25 °C to 50 °C.

import math

R = 8.314
dH_sol = 25000.0                  # J/mol, illustrative, fusion plus mixing
T1, T2 = 298.15, 323.15
ratio = math.exp(-dH_sol / R * (1 / T2 - 1 / T1))
print(round(ratio, 2))            # solubility at 50 C over solubility at 25 C

The factor comes out a little above two. The exercise shows how sensitive the result is to the enthalpy. An error of 5 kJ/mol in ΔH_sol, well within the uncertainty of an estimated enthalpy of fusion, changes the predicted factor by roughly a sixth. Over a wider range the linear plot bends, because the heat-capacity difference between crystal and melt and the temperature dependence of γ both introduce curvature.

Retrograde solubility and other surprises

Not every solute dissolves more on heating. Many gases become less soluble in liquids as the temperature rises, because dissolving a gas is exothermic and loses entropy. The guide on Henry constants and gas solubility treats that case. Some inorganic salts show the same inverse trend. And a few organic systems show a solubility that rises, passes through a maximum and falls, which happens when the enthalpy of solution changes sign over the range, often because of a hydration or solvation equilibrium.

For a liquid-liquid system the analogous behaviour is the upper and lower critical solution temperature. A pair that demixes at room temperature usually mixes on heating, and a σ-profile model reproduces that direction because its Boltzmann factors soften with T. Pairs that demix on heating rely on hydrogen bonds that break with temperature, and these are the cases where the model's hydrogen-bond temperature treatment is tested hardest. The guide on predicting liquid-liquid miscibility covers both.

What the σ-profile does and does not know about temperature

The σ-profile is computed once, from a single DFT calculation in a continuum. It carries no temperature. MFsig computes it with a pinned recipe in a C-PCM continuum of ε = 80 and writes the raw per-segment screening charge to the .mfsig file. Two consequences follow. First, the same file serves every temperature, which is why a solvent library is a one-time investment. Second, anything that changes the molecule with temperature is missing. A flexible solute whose conformer populations shift with temperature has, strictly, a temperature-dependent σ-profile ensemble. For most rigid drugs and all common solvents this is negligible. For long flexible chains it is not, and the guide on conformer ensembles for σ-profiles explains when to care.

The raw σ in the file must be averaged with the model's own scheme before the model runs, at any temperature. COSMO-RS and COSMO-SAC parameterisations assume smoothed profiles. MFsig stops at the σ-profile and the descriptors. The temperature-dependent predictions and their accuracy statements live on MolForge in the solubility matrix.

Key points

  • Temperature enters solubility through the fusion term and through the activity coefficient. A σ-profile model captures both.
  • The van 't Hoff slope, the enthalpy of solution, is the first check against experiment. Slope right and intercept wrong points at the fusion term.
  • The σ-profile is temperature-independent, so one file serves every temperature. Conformer populations are the exception.
  • Gases and some salts show inverse temperature dependence. Lower critical solution temperatures test the hydrogen-bond treatment.
  • Average the raw σ from each .mfsig file before any COSMO-RS or COSMO-SAC calculation.

Questions people ask

Why does solubility usually increase with temperature?
Because dissolving a solid is usually endothermic. The crystal must be broken and the solute mixed into the solvent, and the net heat absorbed appears in the van 't Hoff equation as a positive enthalpy of solution, which makes ln x rise as 1/T falls. Exothermic dissolutions, found for some salts and for gases, show the opposite trend.
Where does temperature enter a σ-profile solubility calculation?
In two places. The fusion term ΔH_fus (1 − T/T_m) shrinks as T approaches the melting point. And the activity coefficient changes because the COSMO-RS type model weighs segment contact energies against RT, so unfavourable contacts matter less when the liquid is hot. The σ-profile itself does not change with temperature.
Can I predict solubility at 50 °C from a value at 25 °C?
Yes with the van 't Hoff equation if you know the enthalpy of solution, which is the enthalpy of fusion plus the enthalpy of mixing. A σ-profile model supplies the mixing part and the melting data supply the fusion part. Over a range of a few tens of degrees the linear van 't Hoff plot is usually adequate.

Further reading

In practice: MFsig provides the σ-profile and descriptors; the downstream solubility and compatibility predictions live on the MolForge platform (solubility matrix, polymer lab) and carry their own accuracy statements there.

Generate a σ-profile from your SMILES