mfsig.com
sigma-profileunitscharge-densityconversion5 min read

Units of a σ-profile, from e/Ų to e/nm² and what the axis means

A σ-profile puts screening charge density in e/Ų on the x-axis and surface area in Ų on the y-axis. Here are the conversions to e/nm², e/bohr² and C/m².

Updated November 28, 2026

A σ-profile is a histogram whose x-axis is screening charge density in elementary charges per square ångström, e/Ų, and whose y-axis is surface area in Ų. One e/Ų equals 100 e/nm², about 3.571 e/bohr² and about 16.02 C/m². Every σ in a .mfsig file is stored in e/Ų, so no conversion is needed before plotting.

What the x-axis measures

Screening charge density is a surface charge divided by an area. When a molecule sits in a cavity inside a conductor, the conductor places a small charge on every patch of the cavity surface. Divide the charge on one patch by the patch's area and you have σ for that segment. Charge is counted in units of the elementary charge e, so the natural unit is e per unit area.

The ångström is the natural length because the segments are a fraction of an atom wide. A segment on a carbon sphere of radius about 2 Å, after the usual scaling of the van der Waals radius, has an area well under a square ångström. The resulting σ values for neutral molecules are small numbers, typically between −0.03 and +0.03 e/Ų for raw segments and within about ±0.02 e/Ų once averaged. Klamt's hydrogen-bond threshold of about 0.0082 e/Ų is a useful mental ruler for where the polar surface begins.

The guide on screening charge density explains why the conductor produces this charge at all. Here the question is only how to read and convert the number.

The conversion table you will actually need

Four unit systems appear in practice. The conversions are exact arithmetic, not model choices, so they can be applied to any profile.

  • e/Ų to e/nm². Multiply by 100. One nanometre is ten ångström, so one square nanometre is one hundred square ångström. A peak at 0.015 e/Ų moves to 1.5 e/nm².
  • e/Ų to e/bohr². Multiply by 0.529177 squared, which is about 0.2800. One bohr is 0.529177 Å, so one square bohr is about 0.28 Ų. The same peak reads 0.0042 e/bohr².
  • e/bohr² to e/Ų. Divide by 0.2800, which is the same as multiplying by about 3.571.
  • e/Ų to C/m². Multiply by about 16.02. The elementary charge is about 1.602 × 10⁻¹⁹ C and one Ų is 10⁻²⁰ m², so one e/Ų is about 16.02 C/m². The same peak reads 0.24 C/m².
BOHR_IN_ANGSTROM = 0.529177
E_IN_COULOMB = 1.602176634e-19

def convert_sigma(sigma_e_per_A2):
    return {
        "e/nm2":   sigma_e_per_A2 * 100.0,
        "e/bohr2": sigma_e_per_A2 * BOHR_IN_ANGSTROM**2,
        "C/m2":    sigma_e_per_A2 * E_IN_COULOMB / 1e-20,
    }

print(convert_sigma(0.015))

A bohr-to-ångström slip is the most common unit error in solvation output. If a profile looks about 3.6 times too wide, or 3.6 times too narrow, suspect an atomic-unit value that was never converted. The guide on units and unit errors in scientific files lists the other traps.

What the y-axis measures and the two ways to normalise it

The y-axis of a σ-profile is area. For each bin of σ, the histogram adds up the areas of all segments whose σ falls inside that bin. The sum of all bins is the total cavity surface area of the molecule, in Ų. This absolute form is what COSMO-RS and COSMO-SAC use, because the number of contacts a molecule can make depends on how much surface it has. The guide on total surface area and molecular size explains why size matters downstream.

Many plots instead divide each bin by the total area. The y-axis then becomes a dimensionless fraction and the bins sum to one. This normalised form is convenient for comparing the shape of a small and a large molecule on one axis, since otherwise the larger molecule towers over the smaller one. It throws away size, so a normalised profile alone cannot tell hexane from methane by height. Always state which form a plot uses. The bin width also changes the height of every bar, and the guide on histogram binning covers that choice.

Worked example, the two peaks of water in four unit systems

Water, SMILES O, gives the clearest illustration because its profile has two well-separated peaks and almost no neutral surface. In the averaged profiles of the COSMO-RS literature the donor peak lies near −0.015 e/Ų and the acceptor peak near +0.015 e/Ų or slightly beyond.

  • In e/nm² the same peaks lie near −1.5 and +1.5.
  • In e/bohr² they lie near −0.0042 and +0.0042.
  • In C/m² they lie near −0.24 and +0.24.

A reader who meets a water profile with peaks near ±1.5 knows at once that the axis is in e/nm². A reader who meets peaks near ±0.004 knows the output is in atomic units. The chemistry has not moved. The guide on the σ-profile of water reads these peaks in detail.

How a .mfsig file stores the unit

A .mfsig file stores σ per segment in e/Ų and segment areas in Ų. The σ-moments stored alongside are statistical moments of the area-weighted σ distribution, so the variance is in (e/Ų)² and the skewness and excess kurtosis are dimensionless. The reaction-field energy and the orbital energies have their own units, and the dipole norm is in debye. The field-by-field anatomy page lists each unit next to each field. The stored σ is the raw per-segment value, not an averaged one, so it is wider than a COSMO-RS profile of the same molecule and must be averaged before any parameterised use. Label the unit on every axis of every plot you make from the file. A reader who meets the figure a year later will not have the file next to it, and e/Ų against e/nm² is a factor of one hundred.

Key points

  • σ is a surface charge density. The standard unit is e/Ų, and the y-axis of a σ-profile is surface area in Ų.
  • One e/Ų is 100 e/nm², about 3.571 e/bohr² and about 16.02 C/m².
  • A profile that looks about 3.6 times too wide or too narrow usually hides an unconverted bohr.
  • Absolute profiles sum to the cavity area. Normalised profiles sum to one and forget molecular size.
  • A .mfsig file stores raw σ in e/Ų per segment. It is not an averaged profile.

Questions people ask

What unit is σ in a sigma profile?
Elementary charge per square ångström, written e/Ų. It is a surface charge density, the induced screening charge on a cavity segment divided by that segment's area. Typical values for neutral molecules lie within a few hundredths of an e/Ų.
How do I convert e/Ų to e/nm²?
Multiply by 100, since one square nanometre is one hundred square ångström. A peak at 0.015 e/Ų therefore appears at 1.5 e/nm². The shape of the profile is unchanged, only the axis labels move.
What is on the y-axis of a σ-profile?
Surface area, in Ų, summed over all segments whose σ falls in each bin. The sum over all bins equals the total cavity surface area. Some authors divide by that total so the y-axis becomes a dimensionless fraction that sums to one.
Why do some codes report σ in e/bohr²?
Quantum-chemistry programs work in atomic units, where length is the bohr. One bohr is 0.529177 Å, so one e/bohr² equals about 3.571 e/Ų. A value that looks about 3.6 times too large is usually an unconverted atomic-unit output.

Further reading

In practice: Every .mfsig file from mfsig.com carries the per-segment σ values this guide describes, so you can rebuild the histogram with any bin width you like. The published samples on the atlas page are a good place to try.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.