mfsig.com
screening-chargecosmocontinuum-solvationelectrostatics5 min read

Screening charge density explained, what the conductor sees

Screening charge density is the surface charge a conductor puts on a molecular cavity to cancel the molecule's potential. Every σ-profile is built from it.

Updated November 28, 2026

Screening charge density is the surface charge a surrounding conductor places on the cavity around a molecule so that the electric potential on that cavity becomes zero. Divided by segment area it is written σ, in e/Ų, and it is the raw material of every σ-profile, or sigma profile when written without the Greek letter. The conductor mirrors the molecule. Where the molecule is electron-rich, the conductor answers with positive charge, and where the molecule exposes a polar hydrogen, it answers with negative charge.

The boundary condition in one paragraph

Imagine the molecule inside a hollow carved out of an ideal metal. A metal cannot sustain an electric field in its interior, so free charge flows onto the surface of the hollow until the potential there is constant. Take that constant as zero. For every point on the surface, the potential from the molecule's nuclei and electrons plus the potential from all the surface charges must add to zero. That single condition fixes the surface charge everywhere.

The screening charges are not independent of each other. A charge on one patch raises the potential on every other patch, so solving for them means solving a linear system in which each segment talks to all the others. Klamt and Schüürmann wrote this system down in 1993 and named the model COSMO, the conductor-like screening model. The guide on C-PCM, IEF-PCM and COSMO compares it with the other continuum formulations that share the same idea.

From a conductor to a real solvent

No real solvent is a perfect conductor. Water at 25 °C has a dielectric constant of about 78, and the conductor corresponds to infinity. Klamt's remedy was to compute the ideal conductor charges and then scale them by a factor

f(ε) = (ε − 1)/(ε + x)

with x = 0.5 in the original COSMO and x = 0 in the C-PCM variant of Barone and Cossi. For water either choice gives a factor close to 0.98, which is why the conductor approximation is so good for polar solvents. For a solvent with ε = 2, such as an alkane, the factor falls to about 0.4 or 0.5, and the conductor picture is much rougher. The guide on the dielectric constant in C-PCM looks at this scaling in detail.

MFsig runs its C-PCM calculations with ε = 80, a water-like value, so the σ it reports is the conductor charge scaled by a factor within about two percent of unity. The σ-profile is usually understood as a property of the molecule in a near-conductor, and this choice keeps it that way.

Why the sign is reversed and why the magnitude is small

Consider the carbonyl oxygen of acetone, SMILES CC(=O)C. The oxygen carries a partial negative charge. The potential it creates on the nearby cavity surface is negative. To cancel it the conductor must place positive charge there, so σ above the oxygen is positive. The two methyl groups are nearly neutral, so the surface above them carries little screening charge and σ is close to zero. The guide on the sign of a σ-profile turns this into a reading rule.

The magnitudes are small because the induced charge is spread over a large surface. A partial charge of a few tenths of an electron on an oxygen is screened by a patch of surface of several square ångström, and the resulting density is a few hundredths of an e/Ų. Klamt's threshold for hydrogen-bonding surface, σ_hb ≈ 0.0082 e/Ų, marks where the surface becomes polar enough to matter. The guide on units of a σ-profile gives the conversions.

The conductor sees the surface, not the atoms

An important consequence of the boundary condition is that the conductor responds to the potential at the cavity surface, not to atomic charges. Two different charge distributions inside the cavity that produce the same potential on the surface produce the same screening charges. The screening charge density is therefore a property of the exposed molecular electrostatics as a whole. A hydroxyl hydrogen buried in an intramolecular hydrogen bond produces little negative σ because its potential is largely cancelled by the nearby oxygen before the surface ever sees it.

This is also why σ depends on geometry. Fold a flexible molecule so that a polar group is shielded, and the σ above it shrinks. The guide on conformer dependence follows this through. The electron density itself is computed by the quantum-chemistry method, so the functional, the basis set and the continuum model all enter σ. The guide on choosing a DFT recipe for σ-profiles explains these choices.

Total charge, a quick consistency check

Gauss's law gives a useful test. In the ideal conductor limit the total screening charge equals minus the total molecular charge inside the cavity. For a neutral molecule the segment charges sum to about zero. For an acetate anion they sum to about +1 e times the scaling factor, and for a protonated amine to about −1 e times the factor. Any residual on a neutral molecule measures how much electron density leaks beyond the cavity, which the finite basis and the cavity radii control.

import numpy as np

# sigma: raw screening charge density per segment, e/A^2
# area:  segment areas, A^2, both read from a .mfsig file
total_screening_charge = np.sum(sigma * area)   # expect about -q * f(eps)
print(round(float(total_screening_charge), 4))

The σ written in a .mfsig file is this raw screening charge per segment divided by segment area. It is not averaged over neighbouring segments. COSMO-RS and COSMO-SAC parameterisations expect an averaged σ-profile, so the raw values must be averaged before any such use. The guide on σ-averaging shows the step.

Key points

  • Screening charge density is the surface charge a conductor places on the cavity to cancel the molecular potential, divided by segment area.
  • Its sign is opposite to the molecular charge beneath it, so acceptor atoms give positive σ and donor hydrogens give negative σ.
  • The conductor result is scaled by f(ε) = (ε − 1)/(ε + x). For water the factor is close to 0.98.
  • σ responds to the potential at the surface, so geometry and intramolecular shielding change it.
  • The sum of σ times area equals about minus the molecular charge. The raw σ in a .mfsig file must be averaged before COSMO-RS use.

Questions people ask

What is screening charge density in simple terms?
Put a molecule inside a hollow in a perfect conductor and the conductor rearranges its charge on the hollow's surface until the electric potential there is zero. The charge per unit area that appears on each patch is the screening charge density σ, in e/Ų. It mirrors the molecular charge beneath it with the opposite sign.
Why does COSMO use a conductor instead of the real solvent?
Because the conductor boundary condition is a simple local equation that is cheap to solve, and a real polar solvent such as water behaves almost like one. The conductor result is then scaled by f(ε) = (ε − 1)/(ε + x) to recover the finite dielectric, which for water is within a few percent of unity.
Is the screening charge a real charge in the solvent?
It is an idealisation. In a real liquid the solvent molecules orient their dipoles and shift their electrons around the solute, and the net effect at the cavity surface is approximately the induced surface charge the model computes. The model replaces that molecular detail with one continuous distribution.
What is the total screening charge on a neutral molecule?
Zero in the ideal conductor limit, since the conductor cancels the molecule's monopole and nothing else needs net charge. For an ion of charge q the total screening charge is −q times the scaling factor. Any residual total on a neutral molecule comes from electron density that leaks outside the cavity.

Further reading

In practice: Every .mfsig file from mfsig.com carries the per-segment σ values this guide describes, so you can rebuild the histogram with any bin width you like. The published samples on the atlas page are a good place to try.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.