Where COSMO-RS struggles, ions, polymers and strong complexes
COSMO-RS is a contact model for neutral molecules in dense liquids. It weakens for ions, long polymers, charge-transfer complexes and proton transfer.
Updated November 28, 2026
COSMO-RS is a model of pairwise surface contacts between neutral molecules in a dense liquid, with the chemistry of each molecule frozen in its σ-profile. It is good within those bounds and predictably weak outside them. Ions break the neutrality assumption. Long polymers break the assumption that size is a simple area and volume. Charge-transfer complexes, proton transfer and metal coordination break the assumption that the electronic structure does not change on contact. Knowing these edges separates a useful prediction from a confident wrong one.
Ions: the screening charge does not sum to zero
For a neutral molecule, the screening charge over the whole cavity sums to zero and the σ-profile is balanced around zero. An ion is different. Its total screening charge equals minus its own charge, scaled by f(ε). The σ-profile of a cation is shifted to negative σ as a whole, an anion's to positive σ. The guide on σ-profiles of ions and zwitterions shows what the profiles look like.
The contact model then has two problems. It has no term for the long-range Coulomb interaction between ions that are not in contact, which is what Debye–Hückel and its extensions describe. And the activity coefficient of a single ion is not measurable, so the model has no reference state for it.
The workarounds are to treat a salt as a neutral ion pair with one combined σ-profile, to treat cation and anion as separate species and report only neutral combinations, or to add an electrolyte term outside COSMO-RS. Ionic liquids are usually handled by the first or second route because the ions are large and the charge is spread. Small inorganic ions in water are the hard case. The guide on ionic liquids and σ-profiles discusses the ion-pair route.
Polymers: the surface is fine, the chain is not
A polymer's surface is a repeat of its monomer surface, so a σ-profile computed for a repeat unit or a short oligomer describes the residual interaction with a solvent reasonably well. That part of COSMO-RS transfers. Three other parts do not.
- The combinatorial term assumes a compact molecule with an area and a volume. A chain of thousands of units has an entropy of mixing described by Flory–Huggins, not by Staverman–Guggenheim.
- Connectivity constrains which patches can touch inside a coil.
- Crystallinity, the glassy state and swelling kinetics are not equilibrium liquid properties at all.
The usual compromise is to take the residual chemical potential of the repeat unit from COSMO-RS, convert it to a Flory–Huggins χ parameter, and use Flory–Huggins for the rest. The guide on Flory–Huggins χ from COSMO-type calculations sets out that conversion.
Strong complexes: the σ-profile is frozen
Every COSMO-RS calculation uses the σ-profile of each component computed in isolation, so contact is assumed to change nothing about the electronic structure. For some pairs that fails.
- Charge-transfer complexes. Iodine in benzene and many donor–acceptor dye systems transfer electron density on contact. The complex has its own surface, which neither profile contains.
- Halogen bonds. A polarisable halogen on an electron-poor carbon presents a σ-hole. The σ-profile sees a weak patch and the misfit term gives a weak attraction. The directional, partially covalent part of a strong halogen bond is underestimated.
- Metal coordination. A ligand binding to a metal centre forms a bond. COSMO-RS has no term for it.
- Proton transfer. Mix a carboxylic acid with an amine and some fraction transfers a proton to form an ion pair. COSMO-RS computes the neutral acid and the neutral amine as written. The hydrogen-bond term captures some of the attraction but not the new species.
The remedy in each case is the same. Decide what species are present, compute a σ-profile for each, including the complex or the ion pair, and treat the mixture as a reactive one with an equilibrium constant. COSMO-RS then supplies activity coefficients for the species it is given. MFsig computes the protonation state exactly as written in the SMILES, with no neutralisation or tautomer handling.
Conformers, solids and temperature
Three softer limits deserve a mention. A flexible molecule has several conformers with different σ-profiles, and one conformer may misrepresent it. MFsig produces one conformer per file.
COSMO-RS describes liquids. A solid's solubility needs the free energy of fusion added from outside. The model does not predict crystal packing, polymorphs or hydrates.
The parameters were fitted around ambient conditions. Supercritical or very low temperature behaviour is outside them.
The σ in a .mfsig file is raw
One more limit sits on the input side rather than in the model. Every COSMO-RS and COSMO-SAC parameterisation expects an averaged σ-profile. A .mfsig file stores the raw per-segment screening charge density from a C-PCM calculation at ε = 80, unaveraged, in e/Ų. It is not that σ-profile and must not be used as if it were. Average with the radius of your parameterisation first, following σ-averaging in COSMO-RS. Skipping this step produces errors that look like model failures and are not.
COSMO-RS answers the question it was asked, which is how neutral surfaces share a liquid, and it answers nothing else.
Worked example: acetic acid and triethylamine
Acetic acid, SMILES CC(=O)O, has a strong donor peak from the acidic hydrogen and an acceptor peak from the carbonyl oxygen. Triethylamine, SMILES CCN(CC)CC, has an acceptor peak from the nitrogen lone pair and a large alkyl surface. Run as written, COSMO-RS pairs the acid's donor with the amine's acceptor and predicts a strong negative deviation from ideality. That much is correct.
What really happens is that a large fraction of the pairs transfer the proton to form triethylammonium acetate, an ion pair with its own σ-profile, much more polar. To model it, compute the σ-profiles of acetic acid, triethylamine and the ion pair, treat the proton transfer as an equilibrium, and let COSMO-RS supply the activity coefficients of the three species. The frozen-profile calculation is a starting point, not an answer.
Key points
- COSMO-RS assumes neutral molecules, compact size and electronic structures frozen on contact. Ions, long polymers and strong complexes violate one of these each.
- Ions need an ion-pair treatment or an external electrolyte term. Single-ion activity coefficients are not meaningful in the base model.
- Polymers take their residual interaction from COSMO-RS and their chain entropy from Flory–Huggins.
- Charge transfer, halogen bonding, coordination and proton transfer create species the isolated σ-profiles do not contain. Compute the species that actually exist.
- The raw σ in a .mfsig file must be averaged before any of this. Input errors are not model limits.
Questions people ask
- Why does COSMO-RS struggle with ions?
- COSMO-RS is a model of surface contacts between neutral molecules. An ion's screening charge does not sum to zero, so its σ-profile is shifted bodily and the long-range electrostatics between ions is not a contact phenomenon at all. Treating ion pairs as neutral units or adding a separate electrolyte term is required, and activity coefficients of single ions are not meaningful in the base model.
- Can COSMO-RS handle polymers?
- Partly. The σ-profile of a repeat unit or short oligomer describes the polymer's surface well, and the residual interaction with a solvent is reasonable. The combinatorial term, the chain connectivity, crystallinity and the glassy state are outside the model. Mapping to a Flory–Huggins χ from the residual part is the usual compromise.
- What kinds of interactions does COSMO-RS miss entirely?
- Anything that changes the electronic structure on contact. Charge-transfer complexes, halogen bonds beyond simple electrostatics, metal coordination, and proton transfer between acid and base all create new species or new bonds. The σ-profile of each isolated molecule does not know about them, so the mixture is predicted as if they did not form.
- Does MFsig fix any of these limits?
- No. MFsig produces the σ-surface of one molecule as written in the SMILES, in one conformer, with the protonation state given. It carries the raw, unaveraged σ per segment, which must be averaged before any COSMO-RS use. The limits above belong to the thermodynamic model and to the chemistry, and the file does not change them.
Further reading
In practice: MFsig writes the raw, unaveraged C-PCM screening charge density of one conformer. It is the input such models start from, not a COSMO-RS-ready averaged profile, and it must be averaged with the parameterisation you use before it enters one.
Generate a σ-profile from your SMILES
Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.