COSMO-RS needs about a dozen fitted parameters, among them the misfit coefficient, hydrogen-bond threshold and averaging radius, all tied to a DFT level.

Updated November 28, 2026

COSMO-RS predicts the thermodynamics of liquids with about a dozen fitted numbers that do not depend on the molecule. The misfit coefficient α', the hydrogen-bond threshold σ_hb and strength c_hb, the averaging radius r_av, the effective contact area a_eff, a few combinatorial coefficients and one dispersion coefficient per element make up the list. That is what makes the method predictive rather than correlative. The catch is that every one of those numbers was fitted to σ-surfaces from one specific DFT level and cavity. Change the level and the numbers no longer fit.

The electrostatic parameters

Two numbers carry the electrostatics. The misfit coefficient α' sets the cost of an unscreened contact, (α'/2) · a_eff · (σ + σ')². Klamt derived a theoretical value from the conductor's dielectric response and adjusted it against experiment. Its fitted value is the single most important number in COSMO-RS, because it scales the whole polar versus apolar contrast. The misfit energy guide explains the form.

The effective contact area a_eff sets how large a patch counts as one independent contact. It appears in the misfit term, the hydrogen-bond term and the exponent of the self-consistent equation. In COSMO-SAC it is fixed at about 7.5 Ų. In COSMO-RS it is one of the fitted parameters. A larger a_eff makes each contact count for more energy and fewer contacts cover a molecule.

The hydrogen-bond parameters

Two more numbers describe hydrogen bonding. The threshold σ_hb, near 0.0082 e/Ų in Klamt's work, decides which patches count as donors or acceptors. The strength c_hb scales the bilinear reward once both patches cross the threshold. Later versions of COSMO-RS make c_hb depend on temperature, because hydrogen bonds weaken faster with heat than plain electrostatics. That adds one or two coefficients.

The threshold is fixed, not fitted per molecule or per element. That is a deliberate design choice. A per-molecule threshold would make the method correlative. A single universal number works because the averaged σ-profile separates polar hydrogens and lone pairs cleanly from the rest across the training set.

The averaging radius and why it is a parameter

The averaging radius r_av is often forgotten in lists of parameters, yet it is one. It sets how far each segment's charge is smoothed over its neighbours before the σ-profile is built. About 0.5 Å in COSMO-RS, larger in COSMO-SAC. A different radius changes the width of every peak in every σ-profile, and the other parameters were fitted to a specific width. The guide on σ-averaging in COSMO-RS shows what the smoothing does.

This is why the per-segment σ in a .mfsig file is stored raw. It is the unaveraged C-PCM screening charge density, not a COSMO-RS σ-profile, and must not be fed to a parameterised code as if it were. Storing it raw lets you apply the exact radius of whichever parameter set you use. Storing it averaged would silently tie the file to one theory.

Combinatorial and dispersion coefficients

The σ-profile carries no information about molecular size beyond total area, so a combinatorial term adds the entropy of mixing molecules of different size and shape. COSMO-RS uses a fitted expression with two or three coefficients multiplying functions of the area and volume. COSMO-SAC uses the Staverman–Guggenheim form with no fitted coefficient of its own, only the standard normalisation constants of UNIQUAC.

Dispersion between apolar surfaces is not in the misfit term. COSMO-RS adds an element-specific dispersion coefficient τ_e for each element, so that the contribution of a hydrocarbon surface to the energy of the pure liquid is captured. These cancel in activity coefficients between similar liquids and matter for vapour pressures and free energies of solvation. COSMO-SAC in its 2002 form had no dispersion term. Later variants added one.

Every parameter is tied to a DFT level

The σ-surface of a molecule depends on the functional, the basis set, the cavity radii, the scaling factor and the dielectric used in the continuum calculation. A more polarising functional gives larger screening charges. A larger cavity gives smaller ones. The parameters absorb those systematic effects. A parameter set fitted to surfaces from one recipe does not describe surfaces from another.

MFsig computes its σ-surfaces with ωB97M-V, def2-SVP, a C-PCM continuum at ε = 80 and Bondi radii scaled by 1.2. That recipe is documented on the recipes page. It differs from the levels that classical COSMO-RS and COSMO-SAC parameter sets were fitted against. Two consequences follow. A published parameter set may need refitting or at least validation before it is used with MFsig surfaces. And the raw σ must be averaged with that set's radius first. The guide on choosing a DFT recipe for σ-profiles discusses why a recipe must be pinned, and the open COSMO-SAC parameterisations guide lists sets whose fitting level is published.

COSMO-RS is predictive because its parameters are universal across molecules, not because they are universal across DFT levels.

Worked example: what a refit would look like

Suppose you have σ-surfaces for a few hundred liquids at a new DFT level and want a COSMO-SAC parameter set for them. The procedure is the one Bell and colleagues documented in 2020 for their open implementation.

  1. Fix the averaging radius and a_eff to the published values, so that the profile width matches the published grid.
  2. Average and bin every σ-surface. Check that water's donor and acceptor peaks still fall beyond ±σ_hb.
  3. Collect a training set of infinite-dilution activity coefficients covering polar, apolar and hydrogen-bonding pairs.
  4. Fit α' and c_hb to minimise the error in ln γ. Keep σ_hb fixed unless the peak positions clearly moved.
  5. Validate on a held-out set before using the parameters for anything else.

With two or three numbers to fit, a few hundred data points are enough. The result is a parameter set that belongs to that level, and should be published alongside it.

Key points

  • COSMO-RS has about a dozen universal parameters. The misfit coefficient α' and the hydrogen-bond pair σ_hb and c_hb carry most of the chemistry.
  • The averaging radius r_av and the contact area a_eff are parameters too. They set the width of the σ-profile that the other parameters assume.
  • Parameters are universal across molecules but not across DFT levels. A new level needs a refit or a validation.
  • A .mfsig file holds raw σ so that any parameter set's radius can be applied. Average first, then check that the set matches the DFT level.

Questions people ask

How many parameters does COSMO-RS have?
About a dozen universal parameters, independent of the molecule. The main ones are the misfit coefficient α', the hydrogen-bond threshold σ_hb and strength c_hb, the averaging radius r_av, the effective contact area a_eff, a few combinatorial coefficients, and one dispersion coefficient per element. The exact count varies between versions and between COSMO-RS and COSMO-SAC.
Are COSMO-RS parameters transferable between DFT levels?
No. The σ-surface depends on the functional, basis set, cavity radii and dielectric used to compute it. The parameters were fitted to surfaces from one specific level. Using them with surfaces from another level introduces a systematic error. A new level needs a refit or at least a validation against known data.
Why is the hydrogen-bond threshold σ_hb fixed rather than fitted per molecule?
COSMO-RS is predictive because its parameters are universal. A threshold fitted per molecule would need data for every new compound. Klamt's value near 0.0082 e/Ų separates polar hydrogens and lone pairs from ordinary polar surface across the whole training set with one number, which is what makes new molecules predictable.
Do I need to refit parameters to use a .mfsig profile with COSMO-RS?
You need two things. First, average the raw per-segment σ in the file with the radius of your parameterisation, because the file holds unaveraged C-PCM data, not a COSMO-RS σ-profile. Second, check that the parameterisation was fitted to surfaces from a comparable DFT level and cavity. If it was not, validate against known activity coefficients before trusting the result.

Further reading

In practice: MFsig writes the raw, unaveraged C-PCM screening charge density of one conformer. It is the input such models start from, not a COSMO-RS-ready averaged profile, and it must be averaged with the parameterisation you use before it enters one.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.