21 CFR Part 11 and computed data, what the rule actually asks
21 CFR Part 11 sets conditions for electronic records in regulated work. What it asks of a computed property and what a result file should carry to support it.
Updated November 28, 2026
21 CFR Part 11 is the United States regulation that sets the conditions under which electronic records and electronic signatures are accepted as equivalent to paper records and handwritten signatures in FDA-regulated work. It does not mention quantum chemistry, and it binds the firm whose system creates, stores and uses a record, not the file itself. A computed property such as a sigma profile becomes a Part 11 record when a firm relies on it to meet a documentation requirement in another regulation. This guide says what the rule asks in general terms, and what a computed result must carry so that a firm's system can meet those asks.
What Part 11 covers and the predicate rule it depends on
Part 11 applies to records in electronic form that are created, modified, maintained, archived, retrieved or transmitted under any records requirement set out in another FDA regulation. Those other regulations are called predicate rules. The predicate rule decides whether a record must exist and for how long. Part 11 decides what makes the electronic form of that record trustworthy. A σ-profile used informally to shortlist solvents may never become a regulated record. The same σ-profile cited in a development report that a predicate rule requires the firm to keep is one.
The regulation has three parts a reader in computational work should know. Subpart B sets controls for electronic records, split into closed systems, where the firm controls access, and open systems, where it does not. Subpart C covers electronic signatures. Section 11.10, the closed-system list, is where most of the practical requirements live. The current eCFR text is short.
The closed-system controls, in the order a computed result meets them
Section 11.10 asks a firm to do about a dozen things.
- Validate the system, so that it performs accurately and consistently and detects invalid or altered records.
- Generate accurate and complete copies of records, in human-readable and electronic form, for inspection.
- Protect records so they remain accurate and retrievable throughout the retention period.
- Limit access to authorised individuals.
- Use secure, computer-generated, time-stamped audit trails that record the date and time of entries and of actions that create, modify or delete records, without obscuring the earlier information.
- Apply operational and authority checks, so that steps run in the permitted order and only permitted people perform them.
- Train the people who build and use the system, hold them accountable in writing, and control the documentation of the system itself.
Open systems, under section 11.30, add measures such as encryption and digital signature standards as appropriate. Subpart C requires that an electronic signature be unique to one individual and not reused, and that it be linked to its record so it cannot be transferred.
What a computed result must carry so a firm can meet those controls
A firm cannot validate, copy or audit a result that does not describe itself. For a σ-profile, four things in the file do most of the work.
The provenance record states the input as typed, including fragments dropped and stereocentres left unassigned, and the outcome, including a convergence flag. The method block states every setting that changes a number, from the functional and basis set to the dielectric constant and the cavity radii, and names a recipe version. The package versions, read at run time, state what software produced the numbers. The content SHA-256 lets the firm, or an inspector, confirm that a copy is accurate and complete.
A .mfsig file carries all four. What a file cannot carry is the rest of the list. Access control, time-stamped audit trails of who requested and who used the result, operational checks and training are properties of the firm's system. Audit trails for computed properties shows how the record inside the file and the record around it fit together, bringing σ-profiles into a LIMS or ELN covers the system side, and data retention for computed results covers the third item on the list.
Why compliance is not a property a vendor can claim
Compliance belongs to the regulated firm. A vendor can describe what its output contains, and the firm decides whether its own system can handle it compliantly. MFsig describes its output on the anatomy page, its audit information on the audit page and provenance on the lineage page. None of those pages is a certificate, and no file should be described as certified or compliant. The right sentence in a filing is that the result carries a provenance record, a method block naming a versioned recipe, package versions read at run time and a content SHA-256, and that the firm's system handles it under its own Part 11 procedures.
One scientific caveat belongs in the same filing. The σ in a .mfsig file is the raw screening charge density per segment, in e/Ų. It is not the averaged σ-profile a COSMO-RS or COSMO-SAC parameterisation expects. If a downstream calculation averaged it, that averaging step is itself part of the regulated workflow and needs its own record.
A worked example, a solvent justification in a development report
A process chemist selects a crystallisation solvent for an active ingredient and the development report must justify the choice with the σ-profiles of the candidates and the API. For each, the firm stores the unchanged result file, writes its content hash into the ELN entry, records the recipe version v1.0.0 and the package versions from the file, and notes who ordered the calculation and when through its own access-controlled system. The averaging step and the downstream comparison are recorded in the firm's calculation notebook with their own versions. When an inspector asks for an accurate and complete copy, the firm produces the file, recomputes the hash, and shows the match. The file supplied the evidence. The firm's system supplied the compliance.
Key points
- Part 11 sets conditions on a firm's system for electronic records, not on a file, and applies when a predicate rule requires the record.
- The closed-system controls include validation, accurate copies, protection, access control, time-stamped audit trails, checks and training.
- A computed result supports those controls by carrying a provenance record, a full method block, run-time package versions and a content hash.
- A .mfsig file carries those four, and the firm's system supplies access control, audit trails and retention.
- Never describe a computed file as certified or compliant. Describe what it carries and how the firm handles it.
Questions people ask
- Does 21 CFR Part 11 apply to a computed σ-profile?
- Part 11 applies to electronic records that a firm creates, modifies, maintains, archives, retrieves or transmits to meet a requirement in another FDA regulation. Whether a given σ-profile is such a record depends on how the firm uses it. If it supports a decision that a predicate rule requires to be documented, the firm's handling of it falls under Part 11.
- What does Part 11 require of a closed system?
- For closed systems the rule asks for validation, the ability to produce accurate and complete copies, protection of records for their retention period, limited system access, secure computer-generated time-stamped audit trails, operational and authority checks, trained users and controls over documentation. These are obligations on the system owner, not on a file.
- Is MFsig Part 11 compliant?
- Compliance is a property of a regulated firm's system and procedures, not of a vendor's output, so the question cannot be answered for a file. What a .mfsig file provides is the material a compliant system needs, a provenance record, the method block, package versions read at run time and a content SHA-256, with its handling described on the audit and lineage pages.
- What should I store with a computed property to satisfy a Part 11 audit?
- Store the result file unchanged, its content hash in a separate record, the recipe definition it names, who requested it and when, and the decision it informed. Keep all of these for the retention period of the record they support, in a form that can be reproduced as an accurate and complete copy.
Further reading
In practice: Each .mfsig file records the method, the package versions read at run time, the geometry convergence flag and a content SHA-256, and no file is written when the SCF does not converge. The lineage and audit pages describe the record in full.
Generate a σ-profile from your SMILES