mfsig.com
cosolventmixturessolubilityformulation5 min read

Cosolvent selection and why mixtures beat single solvents

A cosolvent tunes the solvent's σ-profile continuously, so a mixture can match a solute better than any pure liquid, and σ-profile models find the optimum.

Updated November 28, 2026

A cosolvent lets you tune the solvent's σ-profile continuously instead of choosing from a discrete list. A solute with both a polar head and a greasy body is rarely matched by a single liquid, but a mixture can offer both kinds of surface in the right proportion. That is why many drugs show a solubility maximum in ethanol-water mixtures that exceeds the solubility in either pure liquid. σ-profile models predict the shape of that curve because the mixture enters the theory as a weighted sum of profiles, with no extra parameters.

The mixture is just another σ-profile

In a COSMO-RS-type model the liquid is an ensemble of surface segments. The σ-profile of a pure solvent is the histogram of its segments. The sigma profile of a mixture is the sum of the component histograms, each weighted by mole fraction. Nothing else changes. The model solves for the segment chemical potential μ(σ) in that combined ensemble exactly as for a pure liquid, then integrates the solute's profile over it.

This has two consequences. First, a mixture calculation costs the same as a pure-solvent one, so scanning a composition axis in twenty steps is twenty cheap evaluations, not twenty new DFT runs. Second, the model needs no binary interaction parameters. Water-ethanol, water-propylene glycol and acetone-heptane are all described by the same handful of universal constants. The guide on the universal parameters of COSMO-RS lists them. The caveat is the same as everywhere else, the raw σ in a .mfsig file must be averaged with the model's own scheme before the histograms are summed.

Why the solubility passes through a maximum

Consider paracetamol, with a phenolic hydroxyl, an amide and an aromatic ring. In pure water its aromatic surface pays a large misfit penalty, because water's segments are strongly charged and the ring's are nearly neutral. In pure ethanol the penalty is smaller, but ethanol has fewer strong donors and acceptors per unit volume, so the phenol and amide lose some favourable hydrogen bonds. At an intermediate composition the solute finds water segments for its polar groups and ethyl segments for its ring. The free energy of transfer dips, and the solubility peaks.

The log-linear cosolvency model of Yalkowsky, log S_mix = log S_water + σ_c f_c, interpolates in the cosolvent volume fraction f_c with a single slope σ_c. It is a straight line on a log scale and cannot bend. Where measurements show a maximum, the log-linear model misses it by construction. A σ-profile model bends because μ(σ) responds non-linearly to the ensemble composition, in particular through the hydrogen-bond term, which switches on only when donor and acceptor segments are both present.

A worked composition scan

Here is the arithmetic once a model has delivered the solute's chemical potential in each mixture. The fusion term is constant along the scan, so it only shifts the curve.

import math

R, T = 8.314, 298.15
dG_fus = 56.5 * (442.0 - T)       # Walden's rule, paracetamol Tm about 442 K
mu_pure = 0.0                      # reference, pure supercooled solute
for f_etoh, mu_solv in scan:       # (volume fraction, J/mol) from your model
    ln_x = (mu_pure - mu_solv - dG_fus) / (R * T)
    print(f_etoh, round(math.exp(ln_x), 4))

The list scan is the model's output, a chemical potential at each composition. The shape you look for is a dip in mu_solv at an intermediate fraction. Its depth relative to the ends tells you how much the mixture buys you. Its position tells you where to run the bench points. Converting mole fraction to the volume fraction a formulator uses needs the mixture density, which the model does not provide.

Choosing the cosolvent, not just its amount

A composition scan answers how much. Choosing which cosolvent is the earlier question, and the σ-profile answers it by complementarity. Look at the solute's profile and ask which region of σ is poorly served by the primary solvent. A solute with a strong donor peak in a solvent that lacks acceptors wants a cosolvent with acceptor surface, so a glycol or a glycol ether. A solute with a large non-polar body in water wants a cosolvent with neutral surface that remains miscible with water, so ethanol, propylene glycol or PEG 400. The guide on counting donors and acceptors from the σ-profile shows how to read those peaks.

Then check the cosolvent for its own problems. It must be miscible with the primary solvent over the range you plan to use, see predicting liquid-liquid miscibility. It must be acceptable for the application, which for an injectable is a short list. And it must not create a new problem downstream, such as precipitation on dilution into an aqueous medium, which a composition scan toward zero cosolvent will reveal immediately.

Where cosolvent predictions go wrong

Three failure modes recur. Specific complexation, where a cosolvent forms a stoichiometric complex with the solute, is outside the pair-contact picture. Micelle formation by surfactant cosolvents is a different mechanism altogether. And strongly non-ideal water-cosolvent pairs at low cosolvent content, where water structure dominates, are the hardest region for any continuum-derived model. Treat predictions there as a guide to where to measure, not as a substitute for measuring.

MFsig produces the σ-profiles of the solute and of each solvent component. Mixture predictions, and their accuracy statements, live on MolForge in the solubility matrix. The guide on solvent screening with σ-profiles covers the single-solvent step that comes before any mixture work.

Key points

  • A mixture's σ-profile is the mole-fraction-weighted sum of its components, so mixtures need no extra parameters and no extra DFT.
  • Solubility maxima in mixtures arise from complementary surfaces, and σ-profile models reproduce them where log-linear interpolation cannot.
  • Choose the cosolvent by which region of the solute's σ-profile the primary solvent leaves unserved.
  • Average the raw σ of each .mfsig file before summing histograms for a COSMO-RS or COSMO-SAC calculation.
  • Complexation, micelles and water-rich compositions are where the predictions deserve the least trust.

Questions people ask

Why does a solvent mixture sometimes dissolve more than either pure solvent?
Because the solute has several kinds of surface that no single solvent matches at once. A mixture supplies polar segments for the polar surface and non-polar segments for the rest, lowering the overall misfit cost. The solubility then passes through a maximum at an intermediate composition.
How does a COSMO-RS type model treat a solvent mixture?
The mixture's σ-profile is the mole-fraction-weighted sum of the component profiles. The model solves for the segment chemical potential in that combined ensemble, so a mixture costs no more than a pure solvent and needs no mixture-specific parameters.
Is the log-linear cosolvency model good enough?
It is a useful first guess. The log-linear model of Yalkowsky interpolates log solubility linearly in the cosolvent volume fraction and cannot produce a maximum. Real systems such as drugs in ethanol and water often show a maximum, which a σ-profile based model can reproduce.

Further reading

In practice: MFsig provides the σ-profile and descriptors; the downstream solubility and compatibility predictions live on the MolForge platform (solubility matrix, polymer lab) and carry their own accuracy statements there.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.