mfsig.com
hansen-solubility-parameterscosmo-rssolvent-selectionsigma-profilecoatings5 min read

COSMO-RS vs Hansen solubility parameters, two maps of one terrain

Hansen parameters compress the cohesion of a liquid into three numbers, COSMO-RS keeps the whole σ-profile. Here is what each sees and what Hansen loses.

Updated November 28, 2026

Hansen solubility parameters and COSMO-RS describe the same thing, the cohesion of a liquid and its compatibility with other liquids, with very different amounts of information. Hansen compresses each liquid into three numbers, δD, δP and δH, and predicts compatibility from the distance between two points. COSMO-RS keeps the whole σ-profile and computes a chemical potential. Hansen is faster, more tabulated and easier to draw. COSMO-RS sees things Hansen cannot, above all the difference between a hydrogen-bond donor and an acceptor. Neither replaces the other, and the mapping between them is worth knowing.

What the three Hansen numbers are

Charles Hansen split the cohesive energy density of a liquid into three parts. δD measures dispersion, the London forces every molecule has. δP measures polar, dipole-based cohesion. δH measures hydrogen bonding. Each is the square root of an energy per volume, in MPa to the power one half. The three together satisfy δ_total² = δD² + δP² + δH², where δ_total is the Hildebrand parameter.

Two liquids are predicted to be compatible when they are close in this space. The distance is Ra² = 4 · (δD1 − δD2)² + (δP1 − δP2)² + (δH1 − δH2)², with the factor four on dispersion an empirical choice. A solute is characterised by fitting a sphere in Hansen space around the solvents that dissolve it. The ratio of the distance to the sphere radius, the RED number, ranks candidate solvents. The method is documented on the Hansen Solubility Parameters site and is a standard tool in coatings, inks, adhesives and polymers. The guide on σ-profiles for coatings and inks places it in that context.

What the σ-profile keeps that Hansen throws away

A σ-profile is a distribution, a histogram of surface area against screening charge density. Hansen's three numbers are moments of the cohesive energy, not of the surface. The compression loses four things.

  • Donor versus acceptor. δH is a single number for hydrogen bonding. The σ-profile puts donor surface on the negative side and acceptor surface on the positive side. Chloroform, a donor, and acetone, an acceptor, have comparable δH values and look moderately similar in Hansen space. In the σ-profile they are mirror images beyond the threshold, which is why they attract each other strongly.
  • Distribution shape. Two liquids can have the same δP with very different σ-profiles, one with a few strongly charged patches and one with many weak ones. The misfit energy is quadratic in σ and tells these apart.
  • Temperature. Hansen parameters are tabulated at one temperature. COSMO-RS computes a free energy at any temperature through its Boltzmann factors.
  • Composition. The Hansen method predicts compatibility, not an activity coefficient at a given concentration. COSMO-RS gives the full composition dependence and the two-phase region when there is one.

In exchange, Hansen has δD, which the σ-profile does not carry. Dispersion is not an electrostatic quantity and does not appear in the screening charge. COSMO-RS adds it through element-specific coefficients that cancel in most activity coefficients.

Reading Hansen parameters off a σ-profile

An approximate mapping exists and is useful for triage.

  • δH tracks the surface area beyond ±σ_hb, the hydrogen-bonding area. More donor and acceptor surface per unit volume means a higher δH. The guide on hydrogen-bond decomposition in σ-profiles gives the split.
  • δP tracks the second σ-moment, the variance of the σ distribution, excluding the hydrogen-bonding tails. A wide central distribution means a polar liquid. The σ-moments guide defines the moments.
  • δD is not in the σ-profile. It correlates with refractive index and with the fraction of aromatic or halogenated surface, and must come from elsewhere.

Published schemes regress δP and δH on σ-moments across a few hundred solvents with usable results. They cannot recover the donor and acceptor sign, so they should be used to place a new molecule roughly on a Hansen chart, not to replace a measured sphere.

The σ-profile must be averaged before any of this

Whenever a σ-profile feeds a COSMO-RS or COSMO-SAC calculation, the input must be the averaged profile the parameters were fitted against. A .mfsig file carries the raw per-segment screening charge density from a C-PCM calculation at ε = 80, unaveraged, in e/Ų. It is not the σ-profile a COSMO-RS or COSMO-SAC parameterisation expects, and it must be averaged with that parameterisation's radius first, following σ-averaging in COSMO-RS. The same caution applies to the mapping above. Hydrogen-bonding area counted on raw segments is larger than on averaged ones, and a δH estimated from it will be too high.

Hansen gives you a point on a map. COSMO-RS gives you the terrain the point was taken from.

Worked example: chloroform and acetone

Chloroform, SMILES ClC(Cl)Cl, has one acidic hydrogen under a negative screening patch below −σ_hb, three chlorines with weak positive patches, and no real acceptor. Acetone, SMILES CC(=O)C, has a carbonyl oxygen under a strong positive patch above +σ_hb, two methyls near zero, and no donor.

In Hansen space both have moderate δP and a non-zero δH. They sit a short distance apart and the method predicts them to be compatible, which is true, but says nothing more. In COSMO-RS the two profiles are complementary beyond the threshold. Chloroform's donor peak pairs with acetone's acceptor peak and earns the hydrogen-bond reward. Pure chloroform cannot pair its donor with anything, and pure acetone cannot pair its acceptor. The mixture is therefore more stable than either pure liquid, the activity coefficients fall below one, and a maximum-boiling azeotrope appears. That azeotrope is a textbook fact of chloroform–acetone. Hansen distance cannot predict it, because δH has no sign. The σ-profile does, because it has two sides.

The opposite case follows the same logic. A donor-rich liquid mixed with another donor-rich liquid, both with similar δH, gains nothing from the hydrogen-bond term and pays misfit on its polar surface. Hansen puts the pair close and predicts compatibility. COSMO-RS predicts a positive deviation from ideality. Again the sign of σ carries the information.

Key points

  • Hansen parameters compress cohesion into δD, δP and δH. COSMO-RS keeps the whole σ-profile and computes a chemical potential.
  • Hansen loses the donor–acceptor distinction, the shape of the distribution, temperature and composition. It keeps dispersion, which the σ-profile lacks.
  • δH maps roughly to hydrogen-bonding area and δP to the σ variance. The mapping is for triage, not for replacing a measured sphere.
  • Any σ-profile fed to COSMO-RS, including the raw σ in a .mfsig file, must first be averaged with the parameterisation's radius.

Questions people ask

What are Hansen solubility parameters?
Three numbers per liquid, δD for dispersion, δP for polar and δH for hydrogen-bonding contributions to the cohesive energy density, each in MPa to the power one half. Two liquids are predicted to be compatible when the distance between their points in this three-dimensional space is small. A solute is characterised by a sphere of solvents that dissolve it.
What does COSMO-RS see that Hansen parameters miss?
Hansen's δH does not distinguish a hydrogen-bond donor from an acceptor, so chloroform and acetone look similar even though they are complementary and form a strong azeotrope. COSMO-RS keeps the full σ-profile, in which donor and acceptor surface sit on opposite sides of zero. It also handles temperature and composition, which Hansen parameters do not.
Can I estimate Hansen parameters from a σ-profile?
Approximately. The hydrogen-bonding area beyond ±σ_hb correlates with δH, the second σ-moment with δP, and the total surface area with molecular size. δD is not in the σ-profile at all, because dispersion is not an electrostatic quantity. Several published schemes make this mapping, but it loses the donor and acceptor distinction and should be used for triage only.
Which should a coatings formulator use?
Both, for different questions. Hansen parameters are fast, visual and well tabulated for solvents, resins and pigments, and the sphere method is proven for ranking solvent blends. COSMO-RS gives a physically grounded answer for a new solute, a new solvent or a temperature change. When a .mfsig σ-profile is used for this, its raw σ must first be averaged with the radius of the parameterisation.

Further reading

In practice: MFsig writes the raw, unaveraged C-PCM screening charge density of one conformer. It is the input such models start from, not a COSMO-RS-ready averaged profile, and it must be averaged with the parameterisation you use before it enters one.

Generate a σ-profile from your SMILES

Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.