Ten common mistakes with σ-profiles and how to avoid them
Frequent errors are feeding raw screening charges to COSMO-RS, mixing methods, ignoring protonation, trusting one conformer and dropping the fusion term.
Updated November 28, 2026
The ten mistakes below account for most wrong answers built on σ-profiles. The first and most common is feeding raw screening charges to a COSMO-RS or COSMO-SAC model that expects averaged ones. The rest are mixing levels of theory, computing the wrong protonation state, trusting one conformer of a flexible molecule, confusing units, misreading the sign, binning carelessly, forgetting the fusion term, passing a salt and keeping no record. Each has a short fix.
Mistakes in the hand-over to thermodynamics
1. Feeding raw σ to COSMO-RS
The σ in a .mfsig file is the raw screening charge on each segment divided by its area, in e/Ų. COSMO-RS and COSMO-SAC parameterisations expect a σ averaged over a neighbourhood of about the effective contact area, roughly 7.5 Ų in COSMO-SAC. Raw profiles have sharper, further peaks, and a model fitted to averaged ones will overestimate hydrogen bonding and misfit when fed them. The fix is to apply the averaging step described in the σ-averaging guide before binning, and to say in your method that you did.
2. Mixing levels of theory in one calculation
COSMO-RS parameters are fitted for one functional, basis and cavity. A solute computed with ωB97M-V and def2-SVP paired with solvents from a vendor database at another level introduces an offset nobody has calibrated. Rankings inside one method usually survive. Absolute numbers do not. Compute the whole set under one recipe, or state the mix and treat the result as qualitative.
3. Dropping the fusion term
An activity coefficient describes the liquid. A crystalline solute must also pay to leave its lattice, which enters as a fusion term built from the melting point and the enthalpy of fusion. Skip it and a poorly soluble solid looks soluble. The melting-point guide sets out the term and the approximations when the enthalpy is unknown.
Mistakes in the input molecule
4. Computing the wrong protonation state
Most codes compute exactly the SMILES they receive. No neutralisation, no tautomer choice, no salt handling. Ibuprofen written as the acid gives one profile. Written as the carboxylate, which is the dominant species at physiological pH for an acid with a pKa near 4 to 5, it gives a profile with a large acceptor peak far on the positive side and no donor peak. Decide the state that exists in your solvent and at your pH before you compute, as the protonation guide recommends, and record the decision.
5. Passing a salt and expecting the salt
A multi-fragment SMILES such as a hydrochloride is two molecules. A typical pipeline computes the largest fragment and drops the counter-ion, and a good file records that it did. If your question concerns the ion pair, you need a different calculation, not a different field in the file. Check the identity block for dropped fragments before comparing a salt with its free base.
6. Trusting one conformer of a flexible molecule
A single embedded conformer is a sample, not the molecule. A molecule with an intramolecular hydrogen bond in one conformer and none in another has two different profiles, and the Boltzmann average in solution may resemble neither. For rigid molecules one conformer is fine. For anything with several rotatable bonds and polar groups that can reach each other, compute an ensemble or at least a second conformer and compare.
Mistakes in reading and binning
7. Confusing units
σ appears as e/Ų, e/nm² and e/bohr² in different codes, and the three differ by factors of 100 and about 3.57. A sigma profile that looks a hundred times too wide is in e/nm². A cavity area that is about 3.57 times too large was reported in bohr². Read the units from the file, not from habit. The units guide lists the conversions and the fields where the trap sits.
8. Reading the sign backwards
σ is the screening charge, opposite in sign to the molecular surface. Donors are on the negative side, acceptors on the positive side. A plot with the axis mirrored is easy to produce and easy to misread, and a solvent ranking built on it will be inverted for every hydrogen-bonding solvent.
9. Binning without thinking
A histogram is a choice of bin width and range. Compare two profiles binned at 0.001 e/Ų and 0.002 e/Ų and the second will look twice as tall. Normalise one to probability and the other to area and the comparison is meaningless. Fix the binning for a whole study, keep the area normalisation when the thermodynamics needs area, and state both.
Mistakes in the record
10. Keeping no provenance
A σ-profile without the functional, basis, cavity, dielectric, software versions and a hash of its content cannot be reproduced or defended. A year later, nobody knows whether two files are comparable. Insist on a method block and a content hash in every file, and refuse profiles described only as "COSMO" or "latest".
A worked check on one file
Take any .mfsig file and run through the list before use. Confirm the identity block matches the SMILES you meant, including protonation and dropped fragments. Confirm the geometry converged. Read the method block and confirm that every other file in your comparison has the same one. Note that σ is raw and average it. Read the units. Plot it with a fixed bin width and the sign convention above. Then, and only then, hand it to the thermodynamics with a melting point beside it.
Key points
- Average raw σ before COSMO-RS or COSMO-SAC. A
.mfsigfile holds the raw per-segment value. - One level of theory per comparison. Rankings may survive a mix, absolute numbers do not.
- Compute the protonation state and fragment that exist in your solvent, and check the identity block.
- Units, sign and bin width are the three reasons two correct profiles look different.
- A solid needs a fusion term, and every file needs a method block and a content hash.
Questions people ask
- Can I use the σ-profile from a .mfsig file directly in COSMO-RS?
- Not as it is. The σ in the file is the raw screening charge per segment divided by segment area. COSMO-RS and COSMO-SAC parameterisations were fitted to σ averaged over a neighbourhood of about the effective contact area, and raw profiles are sharper and wider. Apply the averaging step first, then bin.
- Why does my σ-profile look nothing like the published one for the same molecule?
- The usual causes are units, sign and averaging. A profile in e/nm² is a hundred times wider on the axis than one in e/Ų, a reversed sign mirrors the histogram, and a raw profile has sharper and further peaks than an averaged one. Check all three before suspecting the chemistry.
- Does the protonation state in my SMILES matter for the σ-profile?
- It changes everything. A carboxylate puts a large peak far on the positive side that the neutral acid does not have, and the reverse holds for a protonated amine. Most codes compute exactly what the SMILES says, so decide the state that exists in your solvent before you compute.
- Why does a good activity coefficient still give the wrong solubility?
- Because the solute is a solid. The activity coefficient describes the liquid, and the solid must first leave its lattice, which costs the fusion term. Without a melting point and an enthalpy of fusion, or an estimate of them, the solubility of a crystalline compound is not defined by the σ-profile alone.
Further reading
In practice: The free converter turns a σ-profile you already have into a .mfsig file; a reference-grade run computes a new one under the pinned recipe. Prices are on the pricing page and nowhere else.
Generate a σ-profile from your SMILES
Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.