σ-profiles for pharmaceutical formulators, three decisions
A σ-profile tells a formulator which solvents, polymer carriers and excipients an API will sit well with, before the first slurry is made.
Updated November 28, 2026
A σ-profile is a histogram of the polarity of a molecule's surface, computed once from the structure and reused across every solvent question that follows. For a formulator it changes three decisions: which solvent to crystallise or spray-dry from, which polymer should carry an amorphous dispersion, and which excipients an API can share a blend with. The profile does not replace a slurry experiment. It tells you which slurries are worth running.
Decision one, which solvent to crystallise or spray-dry from
A solvent dissolves an API when the two surfaces can touch without paying much misfit energy and when hydrogen-bond donors on one side find acceptors on the other. A σ-profile makes both conditions visible. Take ibuprofen. Its profile has a broad peak around σ = 0 from the isobutyl group and the aromatic ring, a donor spike at negative σ from the carboxylic acid hydrogen, and acceptor density at positive σ from the two carbonyl oxygens. Lay the profile of ethanol over it and the two histograms overlap across the whole range. Lay water over it and water's two sharp polar peaks sit where ibuprofen has almost no surface. The picture matches what the bench knows. Ibuprofen dissolves freely in ethanol and barely in water.
The same comparison works for a spray-drying solvent, where the solvent must dissolve both the API and the polymer and then leave quickly. Acetone, methanol and their mixtures are the usual candidates. A σ-profile cannot tell you the evaporation rate, that comes from vapour pressure, but it can rule out the solvents that will never hold the polymer. The guide on solvent screening with σ-profiles shows how to rank a long solvent list in one pass and which rankings to distrust.
Decision two, the polymer that carries an amorphous dispersion
An amorphous solid dispersion keeps a poorly soluble API in a glassy polymer so that it dissolves faster than the crystal would. The dispersion only lasts if the API and the polymer mix thermodynamically. Itraconazole in hydroxypropyl methylcellulose acetate succinate is the textbook case. Felodipine in polyvinylpyrrolidone and ketoconazole in copovidone are two more. In each case the question is whether the drug and the repeat unit of the polymer have compatible surface polarity.
A σ-profile of the repeat unit, or of a short capped oligomer, gives a Flory–Huggins χ estimate through the misfit and hydrogen-bond terms of a COSMO-RS type model. A small or negative χ favours a stable dispersion. The σ-profile does not know the glass transition, the moisture uptake or the drug loading at which the glass starts to crystallise. Those still come from differential scanning calorimetry and storage studies. What the profile does is shorten the list of polymers worth putting into the spray dryer. The guide on polymer selection for amorphous solid dispersions walks through the repeat-unit choice, and the polymer lab on MolForge runs the χ step from σ-profiles.
Decision three, which excipients an API can share a blend with
Compatibility means two different things in a formulation lab. Chemical compatibility, whether lactose and a primary amine will brown together, is reactivity and a σ-profile says nothing about it. Physical compatibility, whether the API will partition into a lipid, be taken up by a surfactant micelle or plasticise a film coating, is a question of surface polarity and the σ-profile answers it.
Three examples. Glyceryl monostearate has a long nonpolar tail and a small glycerol head, so a lipophilic API such as fenofibrate dissolves into it during hot-melt processing while a polar API such as metformin does not. Polysorbate 80 shows a wide nonpolar region and a polyether head, which is why it solubilises both kinds. Polyethylene glycol 6000, used as a carrier in melt granulation, is almost entirely acceptor and nonpolar surface, so it carries hydrogen-bond donors better than it carries bases with no donor at all. The guide on excipient and API compatibility turns these comparisons into a screening table.
What to decide before you compute anything
A σ-profile is computed for one structure, exactly as written. Three choices belong to the formulator, not to the software.
- Protonation. Ibuprofen as the neutral acid and ibuprofenate are two different molecules with two different profiles. The anion carries a large area of strongly positive σ that the acid does not. Compute the species that exists at the pH of the medium you care about.
- Salts and counter-ions. For ibuprofen lysinate written as a two-fragment SMILES, MFsig computes the fragment with the most heavy atoms and records the lysine as dropped. If the counter-ion matters to your question, compute it as its own job.
- Stereochemistry. Enantiomers have identical σ-profiles because a mirror image has the same surface histogram. Diastereomers do not. An unassigned stereocentre is embedded as one arbitrary isomer and the count is written into the file.
The guide on protonation states and tautomers before a calculation gives a decision procedure for the first choice, which is the one that goes wrong most often.
From the file to a number you can act on
A .mfsig file stores the raw screening charge per segment divided by segment area, in e/Ų. This is not the averaged sigma profile that COSMO-RS and COSMO-SAC parameterisations expect. Feed it to one of those models only after applying the averaging step the parameterisation was fitted with. MFsig stops at the σ-profile and the descriptors in the file: σ-moments, surface area, HOMO and LUMO in solvent, dipole norm and a provenance record with a content hash. Solubility, χ and partition predictions built on it live on MolForge and carry their own accuracy statements. Paste a SMILES at the try page to preview the profile of your API before ordering the file.
A σ-profile does not replace a slurry experiment. It tells you which slurries deserve to be run.
Key points
- Solvent choice for crystallisation and spray drying is a profile overlap question, and the overlap is visible before any solvent is bought.
- Polymer selection for an amorphous dispersion reduces to a χ estimate from the drug and repeat-unit profiles, with glass transition and moisture left to the lab.
- Physical excipient compatibility, partition into lipids and surfactants, follows from surface polarity. Chemical reactivity does not.
- Protonation, counter-ion and stereochemistry are decided by the formulator before the calculation, because the SMILES is computed as written.
- The stored σ is raw per segment and must be averaged before any COSMO-RS or COSMO-SAC use.
Questions people ask
- Can a σ-profile predict which polymer will stabilise an amorphous solid dispersion?
- It gives the thermodynamic half of the answer. From the σ-profiles of the drug and the polymer repeat unit a COSMO-RS type model estimates the Flory–Huggins χ, and a small or negative χ favours a miscible dispersion. Glass transition, moisture uptake and kinetic stability still need calorimetry and storage data.
- Do I compute the σ-profile of an API as the free acid or as its salt?
- Compute the species present in the medium you care about. The neutral acid and the carboxylate have different σ-profiles. For a salt written as a multi-fragment SMILES, MFsig computes the fragment with the most heavy atoms and records the counter-ion as dropped.
- Is the σ-profile in a .mfsig file ready for COSMO-RS?
- No. The file stores the raw screening charge density per segment in e/Ų. COSMO-RS and COSMO-SAC parameterisations were fitted to averaged profiles, so the averaging step must be applied first. Fed raw, the profile gives wrong activity coefficients.
- Does the σ-profile depend on which enantiomer I draw?
- Not for a single stereocentre. A mirror image has the same surface and the same histogram. Diastereomers have different geometries and different σ-profiles, so for molecules with several stereocentres draw the isomer you actually make.
Further reading
In practice: Paste a SMILES on the try page to preview a profile, or start from a published sample on the atlas page. Mixture-level questions continue on the MolForge platform.
Generate a σ-profile from your SMILES