Free converter or reference-grade σ-profile, which one you need
The free converter rewrites a vendor σ-profile you already own as a .mfsig file. A reference-grade run computes a new one under a pinned, recorded recipe.
Updated November 28, 2026
The free converter turns a legacy vendor σ-profile you already own into a .mfsig file. It changes the container, not the chemistry. A reference-grade run computes a new sigma profile from a SMILES under the pinned production recipe and writes a provenance record and a content hash into the file. Choose the converter when you have the data and need the format. Choose the run when you need the data.
What the converter preserves and what it cannot add
The converter reads the σ-profile a vendor package wrote years ago and writes it back in the mfsig/v1.0 schema. The screening charges, the segment areas and the molecule are the ones in your original file. Nothing is recomputed. That is the point. A team with hundreds of profiles from an old licence can read them with one parser, plot them with one script and open them in the 3D viewer without redoing a single SCF.
What the converter cannot do is add physics that was never there. The functional, the basis set, the cavity radii and the dielectric that produced the original numbers still determine them. If the original file does not say which they were, the converted file cannot say either. The provenance of a converted profile is the provenance of its source, and a careful reader should record where the source came from. The guide to converting a legacy COSMO file walks through the fields and the traps.
What a reference-grade run adds
A reference-grade run starts from a SMILES and nothing else. One conformer is built with RDKit ETKDG, seed 42, and relaxed with MMFF94s. A DFT single point follows with ωB97M-V and def2-SVP, density fitting with the def2-svp-jkfit auxiliary basis, a C-PCM continuum with ε = 80 on a cavity of modified Bondi radii scaled by 1.2, and 302 Lebedev points per atom. The SCF converges to 1e-6 Eh or no file is written at all. Every one of those choices is recorded in the method block, together with the package versions read at run time and a SHA-256 of the content. The recipes page lists the recipe in production, and the anatomy page shows every field.
The σ written in the file is the raw screening charge per segment divided by its area, in e/Ų. It is not averaged. COSMO-RS and COSMO-SAC parameterisations expect the averaged profile, so apply the averaging step before any thermodynamics. This applies equally to converted files, whose σ may or may not have been averaged by the original vendor, which is one more thing to check.
Four situations and the answer for each
- You have the vendor file and want to view, plot or parse it with modern tooling. Use the converter.
- The molecule has never been computed. Only a run can produce the profile.
- You are comparing twenty candidates and need every profile under one method. Run them all. A converted outlier from another level of theory will stand out for the wrong reason.
- The number goes into a filing, a patent or a paper. Run it, so the method, the versions and the hash travel with the file. The provenance record guide lists what an auditor will ask for.
A worked example with forty solvents and three new actives
A formulation group holds forty solvent σ-profiles from a vendor licence that lapsed, and three new active ingredients that were never computed. The quick path is to convert the forty for free and run the three. For plotting and for a first visual screen that is fine. For a COSMO-RS ranking it is not quite fine. The forty solvents were computed with one functional and basis, the three actives with ωB97M-V and def2-SVP, and the universal parameters were fitted for a single level of theory. The relative ranking of solvents for one active may survive, because the solvent profiles share a method among themselves. The absolute activity coefficients will carry an uncalibrated offset. The careful path is to convert the forty for archive and tooling, and to recompute the solvents that make the final shortlist under the same recipe as the actives. The pinned-versions guide explains why one method across a set matters more than which method.
Cost, in the only terms that matter here
The converter is free. A reference-grade run is not, see pricing. The real comparison is not money but what each file can carry. A converted file carries your old result in a new container. A reference-grade file carries a result that anyone can recompute from the recipe and verify against the hash. If a converted profile is good enough for a decision today, use it. If the decision will be questioned later, make sure the profile can answer.
Key points
- The converter rewrites an existing vendor σ-profile as a
.mfsigfile and computes nothing new. - A reference-grade run computes a profile from a SMILES under the pinned recipe and records method, versions and a content hash.
- Do not mix levels of theory in one COSMO-RS calculation without knowing the offset you introduce.
- The σ in any
.mfsigfile is raw per-segment screening charge. Average it before COSMO-RS or COSMO-SAC. - Convert for tooling and archive. Run for new molecules, consistent sets and anything that will be audited.
Questions people ask
- What does the free σ-profile converter actually do?
- It takes a legacy σ-profile exported from a vendor COSMO package and rewrites it as a .mfsig file, so your existing results can be read by the same tools, viewers and scripts as new ones. It runs no quantum chemistry. The numbers stay those of the original calculation, and so does their level of theory.
- When do I need a reference-grade σ-profile instead of a converted one?
- When the molecule has never been computed, when every profile in a comparison must share one method, or when the number will be audited. A reference-grade run computes the profile under a pinned recipe and writes the method, the software versions and a content hash into the file.
- Can I mix converted and reference-grade profiles in one COSMO-RS calculation?
- Only with care. COSMO-RS and COSMO-SAC parameters were fitted for one level of theory, and a solute from one method paired with solvents from another shifts the result by an amount nobody has calibrated. For a ranking inside one method the mix is harmless. For an absolute number, recompute the set under one recipe.
Further reading
In practice: The free converter turns a σ-profile you already have into a .mfsig file; a reference-grade run computes a new one under the pinned recipe. Prices are on the pricing page and nowhere else.
Generate a σ-profile from your SMILES
Free converter for a profile you already have, a reference-grade DFT run with its provenance record when it has to be defensible.