C-PCM solves the conductor problem and scales the screening charge by f(ε). At ε = 80 that factor is about 0.98, within two percent of the ideal conductor.

Updated November 28, 2026

In the conductor-like polarisable continuum model, C-PCM, the dielectric constant enters as a single scaling factor. The model solves the electrostatics of a perfect conductor around the molecule, then multiplies the resulting screening charge by f(ε) = (ε − 1)/(ε + x), where x is a small constant. For water, with ε about 78 at 25 °C, that factor is about 0.98. A σ-profile computed at ε = 80 is therefore a conductor σ-profile scaled down by about two percent, which is why a water-like dielectric is the natural setting for sigma profile calculations.

From the conductor to a real solvent

Klamt and Schüürmann introduced COSMO in 1993 with a simple observation. The electrostatic problem of a molecule inside a cavity in a perfect conductor is easy. The potential on the surface must vanish, so the surface charge is found by solving one linear system. The problem of a molecule inside a cavity in a dielectric with finite ε is harder, because the boundary condition involves the normal component of the field on both sides of the surface.

Their approximation was to solve the conductor problem and scale the answer. The exact result for a point charge inside a spherical cavity shows that the dielectric screening energy is (ε − 1)/(ε + 0.5) times the conductor value in the limit of a dipole, and (ε − 1)/ε for a monopole. Klamt chose x = 0.5 as a compromise. Barone and Cossi adopted the same idea in 1998 under the name C-PCM, within the polarisable continuum framework of Tomasi and co-workers, and implementations differ in whether they use x = 0.5 or x = 0.

For high ε the choice of x barely matters. With ε = 80, f is 0.9814 for x = 0.5 and 0.9875 for x = 0, the value the production recipe records. The difference between the two conventions is below one percent, and either is far closer to the conductor than to vacuum.

How f(ε) varies across solvents

The scaling factor is strongly non-linear in ε. A few textbook dielectric constants at room temperature make the point, using x = 0.5.

  • Hexane, ε about 1.9, gives f about 0.38.
  • Acetone, ε about 21, gives f about 0.93.
  • Water, ε about 78, gives f about 0.98.
  • The ideal conductor, ε infinite, gives f equal to 1.

Most of the screening is already present at ε of 20. Going from acetone to water adds five percent. Going from water to the conductor adds two percent. This is why the σ-profile, which is defined in the conductor, is well approximated by any high-dielectric calculation, and why COSMO-RS can treat all solvents from a single conductor reference. The solvent-specific physics lives in the pairing of surface segments, not in ε. The guide on COSMO, COSMO-RS and COSMO-SAC spells out that separation.

What ε changes in a σ-profile, and what it does not

To first order, ε scales every σ value by the same factor. The histogram keeps its shape and every peak moves towards zero by about two percent when going from the conductor to water. To second order, the molecule responds to the weaker reaction field by polarising a little less, which reduces the polar peaks by a further small amount. The two effects go in the same direction and both are small at high ε.

The consequence for reading a file is simple. A σ-profile computed at ε = 80 and one computed in a true conductor differ by a near-constant factor close to 0.98. They are comparable in shape, in the order of peaks and in the sign convention. They are not identical in absolute value, so the dielectric constant belongs in the recipe and in the file. The MFsig production recipe uses C-PCM with ε = 80, and the full method block is on the recipes page.

A second point applies regardless of ε. The σ written to a .mfsig file is the raw screening charge per segment divided by segment area, in e/Ų. It is not the averaged σ-profile that COSMO-RS or COSMO-SAC parameterisations expect and must not be used in their place without the averaging step.

A worked example with acetic acid

Take acetic acid, SMILES CC(=O)O. Its σ-profile has three regions. The methyl surface sits near zero. The carbonyl oxygen produces a positive screening peak, since the solvent must place positive charge next to a negative lone pair. The acidic O–H hydrogen produces a strongly negative peak.

Compute the profile in a conductor and again at ε = 80. The carbonyl peak at, say, +0.0150 e/Ų in the conductor appears near +0.0147 e/Ų in water. The hydroxyl peak at −0.0200 e/Ų appears near −0.0196 e/Ų. Both peaks remain well beyond Klamt's hydrogen-bond threshold of about 0.0082 e/Ų in magnitude. The reaction-field energy, which is also recorded in the file, drops by about the same two percent in magnitude. Nothing qualitative changes. Repeat the exercise at ε = 1.9 and the picture is different, with all peaks shrunk by more than half and the reaction-field energy reduced to a fraction of its water value.

Why a finite ε rather than the conductor itself

If the σ-profile belongs to the conductor, one might ask why a production recipe uses ε = 80 rather than infinity. The honest answer is that the C-PCM formalism in standard quantum-chemistry packages is written for a finite dielectric, and a very high value such as 80 gives a result within two percent of the conductor without stepping outside the framework. Water is also the solvent most readers have in mind, so a water-like continuum makes the recorded HOMO, LUMO and dipole norm directly interpretable. The guide on the dipole moment in solution versus gas phase discusses that interpretation.

The cost of the choice is that two percent, which is the same for every molecule computed under the recipe and therefore cancels in any comparison between them.

Key points

  • C-PCM solves the conductor problem and scales the screening charge by f(ε) = (ε − 1)/(ε + x).
  • At ε = 80 the factor is about 0.98, so a water-like σ-profile is within two percent of the ideal conductor.
  • f(ε) saturates quickly. Most screening is present by ε of 20, and water and the conductor differ by two percent.
  • ε scales the whole profile and barely changes its shape, but it must be pinned and recorded in every file.
  • Raw σ in a file is not the averaged σ-profile that COSMO-RS parameterisations expect, whatever the dielectric.

Questions people ask

What does the dielectric constant do in C-PCM?
C-PCM first computes the screening charge a perfect conductor would place on the cavity surface, then multiplies it by a factor f(ε) = (ε − 1)/(ε + x), where x is a small constant. For water, ε about 78 at 25 °C, the factor is about 0.98. For a non-polar solvent such as hexane, ε about 1.9, it is below 0.4.
Why are σ-profiles computed in a water-like dielectric rather than a conductor?
The COSMO-RS theory is defined for the ideal conductor, and a high dielectric constant brings a C-PCM calculation within about two percent of that limit. Using a finite ε keeps the calculation within the standard C-PCM framework of a quantum-chemistry package. The profile shape is essentially the same, with all σ values scaled by a factor close to one.
Does ε = 80 differ from ε = 78 for a σ-profile?
Hardly. With x = 0, the convention of the production recipe, the scaling factor is 0.9875 at ε = 80 and 0.9872 at ε = 78, a difference in the fourth decimal. Either value is a water-like continuum. What matters is that the same value is pinned in every run.