COSMO-RS vs UNIFAC, predictive theory versus group contribution
UNIFAC builds activity coefficients from fitted group-interaction tables, COSMO-RS from each σ-profile with universal parameters. Here is where each wins.
Updated November 28, 2026
UNIFAC and COSMO-RS both predict activity coefficients in liquid mixtures, and they start from opposite ends. UNIFAC decomposes a molecule into functional groups and reads the energy of each group pair from a table fitted to thousands of experimental data points. COSMO-RS computes each molecule's surface screening charge with quantum chemistry and derives every interaction from about a dozen universal parameters. UNIFAC is faster and often more accurate where its tables are complete. COSMO-RS answers for molecules and isomers that UNIFAC cannot describe. A careful chemist uses both and looks hardest where they disagree.
How UNIFAC builds an activity coefficient
UNIFAC was published by Fredenslund, Jones and Prausnitz in 1975. A molecule is split into groups such as CH3, CH2, OH, CH3CO, ACH for an aromatic carbon with hydrogen. Each group has a volume and an area parameter. Each pair of main groups has a fitted interaction parameter a_mn, not symmetric, that enters a Boltzmann factor. The residual activity coefficient is a sum over the molecule's groups of the difference between the group's activity coefficient in the mixture and in the pure component. A combinatorial term of Staverman–Guggenheim form adds size and shape.
The original model has temperature-independent interaction parameters. Modified UNIFAC, developed in Dortmund, gives each parameter a linear and a quadratic temperature dependence and refits to a far larger database that includes infinite-dilution and excess-enthalpy data.
How COSMO-RS gets to the same number
COSMO-RS starts from the σ-surface of each molecule, averages it, bins it into a σ-profile and solves a self-consistent equation for the chemical potential of each surface patch in the mixture. The pairwise energy has a misfit term quadratic in the sum of two screening charge densities and a hydrogen-bond term switched on beyond a threshold. The route is described in from σ-profile to activity coefficient.
The key difference is where the chemistry lives. In UNIFAC it lives in the table of a_mn values. In COSMO-RS it lives in the σ-profile, which is computed, and the parameters are the same for every molecule. A new molecule costs one DFT calculation and no new data.
Where UNIFAC wins
UNIFAC is unbeatable on three counts when its tables cover the system.
- Speed. Evaluating UNIFAC is microseconds. No quantum chemistry is needed.
- Accuracy on well-studied systems. Modified UNIFAC was fitted directly to vapour–liquid equilibria of common solvents. For an alcohol–ester or ketone–alkane pair it reproduces the data it was fitted to and interpolates well nearby.
- Process-simulator integration. Every simulator ships it.
The price is the table. A group pair without a fitted parameter stops the calculation. Groups are coarse, so proximity effects and most isomers are invisible. And a molecule with an unusual group, a new heterocycle or a fluorinated chain, may not decompose at all.
Where COSMO-RS wins
COSMO-RS gives an answer for any molecule whose σ-surface can be computed. It distinguishes isomers because their surfaces differ. It captures proximity effects because adjacent polar groups change each other's screening charge. It handles new chemistry with no new parameters, which suits early-stage screening of a new active ingredient. The guide on solvent screening with σ-profiles shows that workflow.
It pays for this in two ways. Each molecule needs a DFT calculation, and the σ-profile depends on the conformer and the level of theory. And where UNIFAC was fitted to the exact system, COSMO-RS is typically a little less accurate on it. The universal parameters also depend on the DFT level, so a σ-profile must be used with a parameter set fitted to a comparable level. A .mfsig file in particular holds raw, unaveraged per-segment σ from a C-PCM calculation at ε = 80. It is not the σ-profile a COSMO-RS or COSMO-SAC parameterisation expects, and it must be averaged with that parameterisation's radius before use.
Using both
The two models are complementary, and the best practice is simple.
- Decompose the molecule into UNIFAC groups. If every pair has parameters, run modified UNIFAC.
- Compute the σ-profile and run COSMO-RS or COSMO-SAC with a validated parameter set.
- Where the two agree within the expected scatter, trust the result.
- Where they disagree, look for the cause. A missing proximity effect or an isomer usually points to UNIFAC. A rare functional group with sparse data points the same way. A strongly associating or ionic system points to COSMO-RS.
- For a system with no UNIFAC parameters at all, COSMO-RS is the only option and a quick validation against any available data point is worth the effort.
Some groups use COSMO-RS to generate pseudo-experimental data for fitting missing UNIFAC parameters, a pragmatic bridge where a simulator demands a group-contribution model. The broader comparison with data-driven models is in σ-profiles versus machine-learning solubility models.
UNIFAC knows the answer for the molecules it has seen. COSMO-RS can compute an answer for the ones it has not.
Worked example: the three xylenes in a polar solvent
Ortho-, meta- and para-xylene decompose into the same UNIFAC groups, four ACH and two ACCH3. UNIFAC therefore gives all three the same activity coefficient in any solvent at any temperature. The real liquids differ. The ortho isomer has a small dipole from its two adjacent methyl groups, the para isomer has none, and the meta isomer sits between.
Their σ-profiles differ in the same way. All three have a dominant peak near zero. The ortho isomer's profile is slightly broader with a small asymmetry, because the ring face between the methyls carries a little more negative screening charge and the opposite face a little more positive. The para isomer's profile is the narrowest and most symmetric. The sign convention is explained in σ-profile symmetry and the dipole.
In a polar solvent such as acetonitrile, the broader ortho profile finds slightly more cancelling partners and pays slightly less misfit. COSMO-RS predicts a lower γ∞ for ortho-xylene than for para-xylene, with meta in between. The differences are small, as they are in experiment, but they exist. UNIFAC gives three identical numbers. For separating xylene isomers by extractive distillation, the small difference is the whole question.
Key points
- UNIFAC reads group-pair interactions from a fitted table. COSMO-RS computes a molecule's σ-profile and uses universal parameters.
- UNIFAC is faster and often more accurate where its table is complete. COSMO-RS covers isomers, proximity effects and new chemistry.
- Run both when you can, and investigate where they disagree.
- A .mfsig file is COSMO-RS input after averaging its raw σ. UNIFAC takes a group decomposition instead.
Questions people ask
- What is the main difference between UNIFAC and COSMO-RS?
- UNIFAC splits a molecule into functional groups and takes the interaction energy between each pair of groups from a fitted table. COSMO-RS computes the molecule's surface screening charge with quantum chemistry and derives interactions from a handful of universal parameters. UNIFAC needs data for every pair of groups, COSMO-RS needs a DFT calculation for every molecule.
- Which is more accurate, UNIFAC or COSMO-RS?
- For mixtures whose groups are well covered by experimental data, modified UNIFAC is usually at least as accurate, because it was fitted to that data. For new groups, unusual combinations or isomers that UNIFAC cannot distinguish, COSMO-RS is the only one that gives a specific answer. The honest practice is to run both and compare where they disagree.
- Can UNIFAC distinguish isomers?
- Only when the isomers have different group counts. Ortho-, meta- and para-xylene have the same groups and get identical UNIFAC activity coefficients. Proximity effects, such as two polar groups on adjacent carbons, are also invisible to the standard model. COSMO-RS sees each isomer's own surface and gives different answers.
- Can I use a .mfsig file with UNIFAC?
- No, UNIFAC does not take σ-profiles. A .mfsig file is the input for COSMO-RS and COSMO-SAC after averaging its raw per-segment σ with the radius of the parameterisation. UNIFAC takes a group decomposition of the molecule, which you can derive from the SMILES in the file's identity block, but not from the surface data.
Further reading
In practice: MFsig writes the raw, unaveraged C-PCM screening charge density of one conformer. It is the input such models start from, not a COSMO-RS-ready averaged profile, and it must be averaged with the parameterisation you use before it enters one.
Generate a σ-profile from your SMILES